My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020-193A
CBCC
>
Official Documents
>
2020's
>
2020
>
2020-193A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2021 11:06:19 AM
Creation date
10/14/2020 12:43:44 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
09/22/2020
Control Number
2020-193A
Agenda Item Number
8.C.
Entity Name
One Source Restoration & Building Services, Inc.
Subject
Indian River County Courthouse Parking Garage Rehabilitation
Bid Number
IRC-1801A
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
284
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Bid Number 2020056 <br />Addendum No. 2 <br />Page 2 of 3 <br />Question 3. Plans and specs calls for remove and replace sheetrock ceiling in Elevator Shaft. The location <br />it is showing appears to no longer be an elevator? Is this the right location and if so how are we to access <br />the ceiling? <br />Engineer's Response: Location has been updated to indicate the west elevator shaft. Please reference <br />the attached drawing update. <br />Question 4. Please specified the new traffic coating System required to include manufacturer: <br />a- Pressure wash, primer, base coat and top coat? <br />b- Primer and top coat? <br />c- Just two top coat appl.? <br />Engineer's Response: The allowable manufacturer and product is specified in Section 07 90 20 2.02 b. 3. <br />Question 5. Is there any consideration to remove put new ones and replace Car bumper stops and <br />specified anchoring system? <br />Engineer's Response: No, wheel stops are not to be replaced as part of this contract. <br />Question 6. Please specified the type of the main 2 %" expansion joint on top Deck. <br />Engineer's Response: The expansion joint is specified in Section 32 01 17.612.04 <br />Question 7. a. Is there a preferred manufacturer for the trench drain liner? <br />b. Are alternates to the Stainless -Steel Liner acceptable? <br />Engineer's Response: <br />a. There is no product we are aware of that can be used in this application. <br />b. Alternates may be evaluated. <br />Question 8. What length warranty is required for the staircase coating system? <br />Engineer's Response: There is no Manufacturer warranty specified. The coating shall be covered under <br />the Contractor's Five-year Warranty. <br />Question 9. What is the current exterior coating of the parking garage? <br />Engineer's Response: Unknown. <br />Question 10. Is the required hot applied traffic sealant compatible with the recommended traffic <br />coatings? If not, will the hot applied traffic sealant only be used on the lower two floors? <br />Engineer's Response: We understand they are compatible. Contractors should verify with their <br />respective proposed manufacturers. <br />Question 11. 5001 describes (4) drain bowl clamping rings to match existing and the bid form has a <br />quantity of 24, plan on the 24 quantity? <br />Engineer's Response: Plan on 24 drain bowl clamping rings. Please reference the attached drawing <br />update. <br />F:\Public Works\ENGINEERING DIVISION PROJECTS\1801A IRC Courthouse Parking Garage Rehabilitation\1-Admin\Bids\13id Documents\Bid <br />Dcu m ents\Adde nd u ms\Add-2\Bid 2020056_1 RC-1838_ADD-2_2020826. docx <br />
The URL can be used to link to this page
Your browser does not support the video tag.