My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2021-058A
CBCC
>
Official Documents
>
2020's
>
2021
>
2021-058A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/3/2021 3:50:06 PM
Creation date
4/26/2021 3:05:28 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Work Order
Approved Date
04/13/2021
Control Number
2021-058A
Agenda Item Number
8.J.
Entity Name
Tetra Tech, Inc.
Subject
Well Abandonment and Building Assessment
CCNA2018 Work Order 09
Area
375 82nd Avenue
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Scott Reynolds <br />March 17, 2021 <br />Page 4 <br />Task <br />Timeline <br />Notice to Proceed (NTP) <br />March 17, 2021 <br />Well Abandonment Completed <br />May 17, 2021 <br />Supplemental Site Assessment activities completed <br />As needed <br />Draft Site Assessment Report submitted to IRCDUS <br />Upon completion of <br />the delineation <br />Final. Site Assessment Report submitted to IRCDUS (assumes 7 calendar day <br />IRCDUS review) <br />ASSUMPTIONS <br />Tetra Tech's scope of services and project costs were developed with the following assumptions: <br />• Tetra Tech will review available data provided by Indian River County. <br />• Surveying services are not included. <br />• Permitting fees are not included in this proposal. <br />• The cost proposal does not include any remediation or investigation activities that are not <br />specifically described herein. Additional assessment and remediation may be required. <br />• A Sunshine State One -Call request for subsurface utility location will be completed. This <br />proposal assumes there are no utilities in the vicinity of the USTs. Any utilities in this <br />area must be identified by IRCDUS. Tetra Tech is not responsible for the damage to <br />subsurface infrastructure that is not identified by IRCDUS prior to Tetra Tech initiating <br />AST Closure or Site Assessment activities. <br />• "Face-to-face" meetings with regulators are not proposed as part of this work. <br />• It is assumed that additional restrictions or limitations as a result of COVID-19, weather, <br />or other unforeseen circumstances will not inhibit Tetra Techs level of effort or schedule. <br />• Tetra Tech assumes that Draft reports will have only minor edits by IRCDUS. <br />• Tetra Tech assumes IRCDUS will provide ready access to the Site as needed. <br />PROJECT COST <br />The estimated: costs are based on our current understanding of the project requirements and best <br />estimates of level of effort required to perform the basic services and may be subject to change <br />upon agreement between Indian River County and Tetra Tech. The estimated project costs are <br />shown in the attached Table 1. This project'would be provided as lump sum per task not to <br />exceed $23,550.90, and additional time and materials tasks not to exceed $4,325.32. <br />TE'TR A TECH <br />
The URL can be used to link to this page
Your browser does not support the video tag.