My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2022-014
CBCC
>
Official Documents
>
2020's
>
2022
>
2022-014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2022 3:10:24 PM
Creation date
2/21/2022 3:09:22 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Work Order
Approved Date
01/18/2022
Control Number
2022-014
Agenda Item Number
15.B.2.
Entity Name
Geosyntec Consultants, Inc
Subject
Work Order No. 14 for Annual Permit, Compliance Monitoring, and Reporting for 2022.
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Himanshu H. Mehta, P.E. <br />14 December 2021 <br />Page 6 <br />budget for preparation and attendance (by two Geosyntec personnel) at one meeting with SWDD <br />and/or FDEP, as needed. <br />Phase 2 — Semi -Annual Sampling and Reporting <br />Geosyntec will assist SWDD to perform the semi-annual sampling and prepare the water -quality <br />monitoring reports as required by the WQMP. Geosyntec will assist SWDD with conducting all <br />field sampling preparation activities, including scheduling, staffing, subcontracting, and field <br />equipment preparation. Prior to collecting the groundwater samples in January and July 2022, <br />Geosyntec will perform water -level measurements from the 56 groundwater monitoring wells <br />and 1 staff gauge (SG -12). Geosyntec will then perform semi-annual sampling of the Class I <br />landfill and C&D debris disposal facility groundwater monitoring wells in January (34 wells) <br />and July (25 wells) of 2022. We will also perform semi-annual (January and July) sampling of <br />the surface water site (SW -2), if its discharging from the stormwater pond. <br />It is estimated that data collection and sampling will take five (5) full days in January and four <br />(4) full days in July for the semi-annual monitoring and reporting for the Class I landfill and <br />C&D debris disposal facility. Geosyntec will deliver the samples to ENCO laboratory for <br />analytical testing under SWDD's contract (i.e., ENCO laboratory will directly invoice SWDD). <br />The laboratory analytical testing will be conducted by ENCO testing laboratory. The samples <br />collected from the Class I landfill monitoring wells will be analyzed for the routine monitoring <br />parameters listed in paragraph 7 of the WQMP and in accordance with paragraph 62- <br />701.510(5)(c) & (7)(a), F.A.C. The samples collected from the C&D debris disposal facility <br />monitoring wells, with the exception of the quarterly assessment wells, will be analyzed for the <br />routine monitoring parameters listed in paragraph 8 of the WQMP and in accordance with 62- <br />701.739(8)(d), F.A.C. The samples from the surface water site (SW -2) will be analyzed for the <br />list of parameters listed in Section I11.2 of the Class I Landfill WQMP, as required by paragraphs <br />62-701.510 (5)(d) and (7)(b), F.A.C. Geosyntec will assist SWDD in coordinating the analytical <br />testing activities with ENCO, notify FDEP prior to sampling as required by the WQMP, review <br />and evaluate the analytical test results, and prepare the semi-annual reports. <br />The results of water -quality sampling under the WQMP will be presented in a report supported <br />by attachments containing chain -of -custody sheets, field notes and observations, water sampling <br />logs, maps, analytical results, and any other applicable materials. The reports will include <br />ground water completion report form and ground water elevation contour map, both signed and <br />sealed by a Florida registered professional engineer. These reports will be submitted to SWDD <br />for review prior to submittal to FDEP. The reports (in Adobe format) and analytical data <br />Electronic Data Deliverable (EDD) will be submitted electronically to FDEP using the ADaPT <br />NCP2021-3441/JL21090 2022 Compliance Monitories Proposal Final Am <br />
The URL can be used to link to this page
Your browser does not support the video tag.