2022-050
CBCC
>
Official Documents
>
2020's
>
2022
>
2022-050
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2022 10:09:09 AM
Creation date
4/6/2022 3:25:27 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Change Order
Approved Date
03/08/2022
Control Number
2022-050
Agenda Item Number
8.G.
Entity Name
All Webbs Enterprises, Inc.
Subject
Change Order No. 1, Well Field Feasibility Expansions Study
at the North County Water Treatment Plant,
Well N7 Formation Water Disposal Measures and Gopher Tortoise Management
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(Ak) <br />All WEBBS <br />February 25, 2022 <br />Jon Friedrichs <br />Principal Hydrogeologist <br />ILA Geosciences, Inc. <br />CELL: (561) 459-9355 <br />Dear Jon, <br />RE: IRC N7 Request for Change Order Discharge Requirements and Tortise Impact <br />Reason <br />The recently issued IRFWCD discharge permit #22-07 and the special conditions in that permit as <br />the reason for the additional costs and time. The Special Conditions for Permit No. 22-07 for <br />temporary discharge of formation water associated with deepening IRCDUS existing production <br />well N7 from the UFA to the APPZ/Lower Floridan Aquifer, into Sublateral G-7 (815' Street) Canal <br />Located in NW '/< of SE % of Section 32-31-39 include: <br />(1) Off-site discharge of formation water associated with proposed well deepening shall not <br />exceed 1,250 PPM total dissolved solids (TDS), and turbidity shall not exceed existing <br />background Nephelometric Turbidity Units (NTU) of receiving wasters within canal system. <br />(2) TDS and turbidity of said off-site discharge water shall be monitored several times daily. <br />If/when above limits of TDS and turbidity are exceeded, Permittee is to notify David E. Gunter, <br />Superintendent of Indian River Farms Water Control District, of remedial action taken to bring <br />operation within permit limits. <br />(3) Permittee shall advise the District (Phone: 772-562-2141) in advance of commencement <br />and upon completion of proposed well deepening operations. <br />The discharge requirements in the permit are extremely high, the system proposed below is an <br />attempt to meet the requirements. Additional work may be required depending on the water <br />quality encountered during deepening and David Gunter's remedial actions. <br />Pricing <br />Description <br />Quantity <br />Units <br />Unit Cost <br />Extended Cost <br />Silt Fence <br />1 <br />LS <br />$ 4,000.00 <br />$ 4,000.00 <br />Frac Tanks <br />4 <br />LS <br />$ 5,778.75 <br />$ 23,115.00 <br />Freight Tanks <br />4 <br />LS <br />$ 2,673.75 <br />$ 10,695.00 <br />Cleanout <br />Tanks <br />4 <br />LS <br />$ 2,673.75 <br />$ 10,695.00 <br />Settling Tank <br />1 <br />LS <br />$ 7,935.00 <br />$ 7,935.00 <br />Filter Sand <br />1 <br />LS <br />$ 5,520.00 <br />$ 5,520.00 <br />Pumps <br />1 <br />LS <br />$ 13,340.00 <br />$ 13,340.00 <br />Pipe Ramps <br />50 <br />LS <br />$ 144.90 <br />$ 7,245.00 <br />Box <br />1 <br />LS <br />$ 4,830.00 <br />$ 4,830.00 <br />Floc Logs <br />10 <br />LS <br />$ 506.00 <br />$ 5,060.00 <br />subtotal <br />$ 92,435.00 <br />