My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1968-009
CBCC
>
Resolutions
>
1960's
>
1968
>
1968-009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/22/2022 11:00:17 AM
Creation date
4/22/2022 10:57:07 AM
Metadata
Fields
Template:
Resolutions
Resolution Number
1968-009
Approved Date
02/21/1968
Resolution Type
Adopting a Building Code
Subject
Adopting Building Code, Electrical & Plumbing Codes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M Single outlets or taps for signaling transformers, bell - <br />ringing transformers, clocks and similar low current consuming <br />appliances or equipment need not be counted when the location of the <br />tap or outlet precludes the use of the tap or outlet for other purposes <br />than for which it was installed. <br />(g) M aximum number outlets per circuit for lights and <br />receptacles: <br />Light {cutlets---------------- --------- 9 8 7 6 5 4 3 2 1 0 <br />Receptacles ----------------------------0 1 12 2 3 3 4 4 5 <br />Section 27. GENERAL REQUIREMENTS. <br />(a) Approved rigid metal conduit surface metal raceways or <br />electrical -metallic tubing shall be required for light, heat and power <br />In the wiring of apartment buildings for three families or more, In <br />churches, schools, hotels, theaters, public buildings, commercial <br />buildings, manufacturing establishments, private clubs, or similar <br />occupancy, <br />(b) It shall be unlawful for any person to place, tape around <br />or otherwise conceal any Improperly Made joint on any light, heat, <br />or power circuit. <br />(c) The wiring for all electric ranges shall be a minimum wire <br />capacity of 40 amperes, to an approved receptacle, for ranges of <br />8 3/4 KW capacity or less. Conductor size shall be of at least 30 <br />ampere capacity. When oven circuit unit is separate from surface <br />unit, each unit shall be installed on a separate circuit, served with <br />conductors of not less than 30 ampere capacity. An approved method <br />of connection shall be provided for each unit. (A range as referred <br />to above would be a complete cooking unit, consisting of both oven <br />and surface burners). <br />(d) The wiring for all water heaters shall be in a minimum <br />wire capacity of 20 amperes. Water heaters of 1, 000 watts or over <br />shall operate on not less than a 208 volt circuit. Nonautomatic water <br />25 <br />
The URL can be used to link to this page
Your browser does not support the video tag.