Laserfiche WebLink
000- Since 1988 <br />Florida's Leading Engineering Source <br />Environmental • Geotechnical - Construction Materials Testing - Threshold and Special Inspections - Plan Review $ Code Compliance <br />Mr. Anthony J. Donadio <br />Donadio & Associates, Architects, P.A. <br />2001 9th Avenue, Suite 308 <br />Vero Beach, Florida 32960 <br />RE: Report of Geotechnical Exploration <br />North County Library Addition <br />1001 County Road #512, Sebastian, Florida <br />GFA Project No. 20-9197.00 <br />Dear Mr. Donadio: <br />April 24, 2020 <br />GFA International, Inc. (GFA) has completed the subsurface exploration and geotechnical <br />engineering evaluation for the above referenced project in accordance with the geotechnical <br />and engineering service agreement for this project. The scope of services was completed in <br />accordance with our Geotechnical Engineering Proposal No. 20-9197.00 dated March 9, 2020, <br />planned in conjunction with and authorized by you. <br />EXECUTIVE SUMMARY <br />The purpose of our subsurface exploration was to classify the nature of the subsurface soils and <br />general geomorphic conditions at the site and evaluate their impact upon the proposed <br />construction. This report contains the results of our subsurface exploration and our engineering <br />interpretations of these with respect to the project characteristics described to us, including <br />providing recommendations for foundation design and site preparation. <br />Per our prior telephone discussions and email correspondence with you, GFA understands that <br />a single -story addition is planned for the North County Library in Sebastian, Florida. We have <br />been provided with a site plan showing the location of the proposed construction on the <br />property. <br />Specific design loads have not been provided to GFA. For the foundation recommendations <br />presented in this report, we assumed a maximum wall loading of 3 kips per linear foot and a <br />maximum column load of 35 kips. <br />The recommendations provided herein are based upon the above considerations. If the stated <br />conditions are incorrect or if the project description is revised, please inform GFA so that we <br />may review our recommendations with respect to any modifications. <br />Two (2) standard penetration test (SPT) borings, advanced to an approximate depth of 20 feet <br />below the existing ground surface, were performed for this study. The subsurface soil conditions <br />encountered at the boring locations generally consisted of very loose to medium dense fine <br />sand (SP), fine sand with silt (SP -SM), and silty fine sand (SM) to the termination depths. <br />607 NW Commodity Cove • Port St. Lucie, Florida 34986 - (772) 924-3575 • (772) 924-3580 (fax) • www.teamgfa.com <br />