My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2022-075A
CBCC
>
Official Documents
>
2020's
>
2022
>
2022-075A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/7/2022 3:16:34 PM
Creation date
7/7/2022 1:03:33 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
04/12/2022
Control Number
2022-075A
Agenda Item Number
12.G.2.
Entity Name
Proctor Construction Company, LLC
Subject
North County Library Expansion
Project Number
IRC-2009
Bid Number
2022021
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
596
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
North County Library Addition Geotechnical Exploration Report <br />1001 County Road #512, Sebastian, Florida April 24, 2020 <br />GFA Project No. 20-9197.00 Page 2 of 10 <br />Considering the results of our field exploration program, the subsurface soil conditions at the <br />boring locations are generally favorable for support of the proposed structure on shallow <br />foundations. A maximum allowable soil bearing pressure of 2,500 psf may be used for <br />foundation design. <br />The subgrade soils should be improved (densified) with compaction from the stripped grade <br />prior to constructing the building pad. Before placing fill to achieve final grade, the upper 2 feet <br />of soil below stripped grade should be compacted to a minimum of 95 percent maximum dry <br />density as determined by the modified Proctor test (ASTM D 1557). Fill (including stem wall <br />backfill) should be placed in 12 -inch thick lifts and compacted to achieve a minimum 95 percent <br />modified Proctor maximum dry density. After completing the footing excavations, the bearing <br />subgrade to a depth of 2 feet should be compacted to not less than 95 percent modified Proctor <br />maximum dry density. <br />We appreciate the opportunity to be of service to you during this phase of the project and look <br />forward to a continued association. Please do not hesitate to contact us if you have any <br />questions or comments, or if we may further assist you as your plans proceed. <br />Respectfully Submitted, <br />GFA International, Inc. <br />Florida Certificate of Authorization No. 4930 <br />This item has been digitally signed and sealed by John Kent, P.E. on the date <br />adjacent to the seal. Printed copies of this document are not considered signed <br />and sealed and the signature must be verified on any electronic copies. <br />John Kent, P.E. Erik Soderstrom, E.I. <br />Senior Project Engineer Geotechnical Department Manager <br />Florida Registration No. 63218 <br />Distribution: Mr. Anthony J. Donadio — Donadio & Associates Architects, P.A. 1 pdf <br />6FF <br />
The URL can be used to link to this page
Your browser does not support the video tag.