Laserfiche WebLink
ORDER NO. PSC -2022 -0203 -PAA -EQ <br />DOCKET NO. 20220072 -EQ <br />PAGE 46 <br />t'LIJJV.Vt1 t"VYY nm of t,tlstlt 1.V1Vll"HIV .r <br />(Continued from SheetNo.10.316) <br />IV. PLANT DISPATCHABTLITY/CONTROLLABII,TTY <br />Attachment A <br />'sneer iso. tu..at i <br />• Provide the following operating characteristics and a detailed explanation supporting the performance capabilities indicated. <br />+ Ramp Rate (MW/minute) <br />+ Peak Capability (%o above Committed Capacity) <br />+ Iafinimum power level ("/• of Coaunitted Capacity) <br />+ Facility Tuunnarotind ,rime, Hot to Hot (liours) <br />+ Start-up 11mc front Cold Shutdown (harts) <br />s Unit Cycling (4 cyclestyr) <br />+ MW and MVAR Control (AGC, Mamtal.Other (glease explain)) <br />V. srrING AND IdCFNSING <br />• Provide a licensing/permitting milestone schedule which lists all permits, licenses and variances rectuired to site the Facility <br />'Itte milestone schedule shall also identify key rtolestont dates for baseline nxrrtiWriM application prepailhott, agowy review, <br />oerfification and licertsing/siting board approval, and agency permit issuance. <br />• Provide a lieensinglpormittin>;g plan that addresses the issues of air emissions, water use, wastewater discharge, wctfand,, <br />endangered species, protected properties, solid waste, surrounding Land use, zoninR for the Facility, associated linear facilities, <br />and support of and opposition to the Facility. <br />+ List the emissiottefYluent discharge limits the Facility will meet, and describe in detail the pollution control equipment to be <br />used to meet these limits, <br />VT. FACILITY DEVELOPMENT AND PERFORMANCE <br />• Submit a detailed engineering, Procurement. construction, startup and commercial operation schedule. 'Ma schedule shall <br />include trilestdnes for site acquisition, engineering phases, selection ofthe tnalor equipment vendors, architect engineer, EPC <br />contractor, and Facility operator, steam host integratim and delivery of major equipment. A discussion ofthe current status of <br />each milestone should also be included where applicable. <br />• Attach a diagram of the power block arrangement. Provide a list of the major equipment vendors and the name and nuxlel <br />number of the major equipment to be bisdalled. <br />• Provide a detailed description of dw proposed envirorauentat control technology for the Facility and describe the eapalilitie <br />ofthe proposed technology, <br />• Attach prelirnimary flaw diagrams for the steam system, water system, and fuel system, and a main electrical one line diagra n <br />for die Facility, <br />• State die expected heat rate (HHV) at 75 degrees Fahrenheit for leads of 100%, 75%, and 50%. [n addition, attach a <br />preliminary heat balance for the Facility. <br />• [NOTE: add any requirements related to demonstrating that the facility meets the requirements under the statute or applicable <br />rules) <br />(Continued on Sheet No.10.318) <br />Issued l*- & L Romig, Director, Rates and Tariffs <br />Effective: May 22, 2007 <br />IAS <br />