Laserfiche WebLink
CLI <br />40 <br />r <br />I <br />Depth of Cover and Pipe Elevation: Unless otherwise <br />shown on the drawings, or otherwise authorized by the <br />Engineer, all pipe shall have a minimum cover of 36 <br />inches. Contractor shall. determine top of pipe <br />elevation and top of ground elevation for every two <br />joints of pipe installed using a level. ripe must have <br />the minimum cover described above and must be within <br />+r-0.2 feet of the top of pipe elevation indicated on <br />the drawings. installed pipe which does not meet these <br />requirements shall be reinutalled until it does meet <br />these requirements. Contractor shall record top of- <br />pipe <br />£pipe and top of ground elevations and the locations of <br />where these elevations were determined and submit this <br />information to Engineer or his representative. <br />Engineer reserves the right to have Contractor excavate <br />and check top of pipe and top of ground elevations to <br />see if they conform to the aforementioned requirements, <br />at no cost to owner. <br />END OF SECTION <br />02625-5 <br />