2023-193
CBCC
>
Official Documents
>
2020's
>
2023
>
2023-193
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/9/2023 1:24:47 PM
Creation date
10/9/2023 1:21:41 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Agreement
Approved Date
09/12/2023
Control Number
2023-193
Agenda Item Number
8.K.
Entity Name
Precision Contracting Services, Inc.
Subject
Agreement for Annual Fiber Optic Engineering, Design Material, Supplies, and Installation
Area
Various throughout Indian River County
Bid Number
2023056
Document Relationships
2023-194
(Cover Page)
Path:
\Official Documents\2020's\2023
2023-195
(Cover Page)
Path:
\Official Documents\2020's\2023
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f) When a conduit installation changes from underground to above -ground, make the <br />change a minimum of 6" below finished grade. <br />g) Install an expansion fitting when conduit crosses an expansion joint of a structure. <br />h) Use couplings and expansion joints made of the same material as the conduit. <br />i) Ensure that all joints are made as specified by the manufacturer and are waterproof. <br />j) For installations not specifically shown, install the conduit in accordance with <br />National Electrical Code (NEC) and/or National Electrical Safety Code (NESC) <br />requirements. <br />k) When earth backfill and tamping is required, place backfill material in layers <br />approximately 12" thick, and tamp each layer to a density equal to or greater than <br />the adjacent soil. <br />1) When trenching instead of boring, saw cut and repair all pavement and sidewalks <br />encountered. When backfilling trenches in existing pavement, use a commercially <br />available sand -cement (approximately 10:1 mix ratio). <br />m) Provide a standard clearance between underground control cable and electrical <br />service cable or another parallel underground electrical service cable that meets <br />National Electrical Safety Code requirements. <br />n) Install conduit for electrical and low -voltage systems as shown on the plans or <br />referenced to FDOT Design Standards, Index No. 17721. Consider the locations of <br />conduit as shown on the plans as approximate. Construct conduit runs as straight as <br />possible, and obtain the Engineer's/Owner's approval of all major deviations in <br />conduit locations from those shown on the plans. <br />o) Provide an outer duct and innerduct that is suitable for underground use in an <br />ambient temperature range of -32° to 130° F, without degradation of material <br />properties. <br />p) Provide outer duct and innerduct that is resistant to benzene, calcium chloride, <br />ethyl alcohol, fuel oil, gasoline, lubricating oil, potassium chloride, sodium chloride, <br />sodium nitrate, and transformer oil, and is protected against degradation due to <br />oxidation and general corrosion. <br />q) Provide outer duct and innerduct with an outer diameter to a minimum wall <br />thickness ratio that complies with ASTM — D3035, Standard Dimension Ratio (SDR) <br />13.5. <br />r) Provide outer duct and innerduct that meets or exceeds the following: <br />1. ASTM — D1238: Tensile Strength —3000 PSI minimum Elongation —400% <br />minimum <br />2. ASTM — D1238: Melt Index — 0.4 maximum <br />3. ASTM — D1505: Density — 0.941— 0.9 55 g/cc <br />4. ASTM — D1693: Condition B-20% failure, maximum <br />5. ASTM — D2444: Impact — NEMA Standards Publication TC 7 <br />6. ASTM — D3350: Cell Classification — 334420 or 34420 <br />s) Provide outer duct and innerduct with the coefficient of fiction of 0.09 or less. <br />t) Provide 0.5 inch, pre -lubricated, woven polyester tape with a minimum rated tensile <br />strength of 2,500 lbs. <br />7.4.2 HDPE Outer Duct <br />24 <br />