Laserfiche WebLink
0 <br />0 <br />.�imfcr�� <br />! 3.03 INSTALLATION <br />A. Install roof window units. hardware, operators. accessories and other roof window components according to roof window <br />manufacturer's installation instruction sheets. <br />r <br />B Attach mounting brackets and center roof window In opening. Set units plumb, level true to line. wilhout warp or rack in homes <br />or sash. <br />C. Check sash operation in all modes. <br />O. Install flashings in accordance with roof window manufacturer's instructions. <br />E. Apply sealant between frame and rough opening. <br />F. Extend vapor barrier to Interior face of roof window frame and attach. <br />3.04 INTERIOR FINISHING <br />A. Finish interior woodroof window components according to roof window manufacturer's instructions. <br />3.45 ACCESSORIES <br />A- Pleated Shades: Install pleated shades as recommandad by roof wlndow manufacturer. <br />B. Remote Roof Window Operator: Install remote roof window operator on venting unlis where indicated on Drawings according to <br />roof window manufacturer's instructions. <br />3.06 CLEANING <br />A. Clean surfaces to remove dirt. Use cteanfng materials specifically recommended by roof window manulaciurer. <br />B. Remove debris from work slle. <br />C. Leave ventilating roof window units in closed position. <br />D, Protect interior and exterior of roof window units until structure is sealed from the weather. <br />07812-7 <br />ENO OF SECTION <br />