My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000-090
CBCC
>
Official Documents
>
2000's
>
2000
>
2000-090
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/12/2024 10:34:43 AM
Creation date
3/12/2024 10:17:28 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Agreement
Approved Date
03/21/2000
Control Number
2000-090
Agenda Item Number
11.H.2.
Entity Name
Tri-Sure Corp.
Subject
Rockridge Sewer Project
Bid Number
2028
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
222
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C-1 <br />4 <br />M <br />f SECTION 02675 <br />DISINFECTION AND ItYDROSTATIC TESTING OF WATER SYSTEM <br />PART 1 — GENERAL <br />lel DESCRIPTION OF WORK <br />1.1.1 Disinfection of potable water system. <br />1.1.2 Hydrostatic Testing <br />1.1.3 Testing and reporting results <br />1.2 REFERENCES <br />1.2.1 ANSIIAWWA B300 - Standard for Hypochlorites. <br />1.2.2 ANSI/AWWA B301 - Standard for Liquid. Chlorine. <br />1,2.3 ANSIIAWWA B302 - Standard for Ammonium Sulfate. <br />1.2.4 ANSIIAW'WA B303 - Standard for Sodium Chlorite, <br />1.2.5 ANSIIAWWA 0601 - Standard for Disinfecting Water Mains, except that the tablet <br />method specified in Section 5.1 will not be acceptable. <br />1.3 SUBMITTALS <br />1.3.1 Test Reports: Indicate results comparative to specified requirements. <br />t 1.3.2 Certificate: Certify that cleanliness of water distribution systcm meets or exceeds <br />specified requirements. <br />I <br />t 1.4 REPORT DOCUMENTS <br />t 1.4.1 Disinfection report; record: <br />1. <br />1. Type and form of disinfectant used. <br />1 <br />2. Date and time of disinfectant injection start and time of completion. <br />{ 3. Test locations. <br />1 4. Initial and 24 hour disinfectant residuals (quantity in treated water) in ppm for <br />{ each outlet tested. <br />L- 5. Date and time of flushing start and completion. <br />02675-1 <br />Dunlectim h Hydrostatic Twins or <br />f wain and K'atte*atn $yst:m <br />` GSenn Lsc.Pk t rks'lrnyecl - krxssalaP ?P.aq Impnnmr�atY,tprS IkY,uftcerun oat nYa�,u f PYi�a <br />
The URL can be used to link to this page
Your browser does not support the video tag.