Laserfiche WebLink
7 <br />4i® <br />Marginal characteristics of this facility include: <br />• There is limited exposure to large and small wind-borne debris. <br />• The building has a flat, lightweight roof system. <br />• The building is within the Vulnerability Zone of two Section 302 facilities but has low release <br />potential. <br />Non-compliant characteristic of this facility include: <br />• Several hazards within lay -down range of building. <br />• The building has unprotected windows and doors that lead into shelter areas. <br />The building's roof exceeds a 40 foot span <br />Retrofit Recommendation: <br />Major <br />• Have a structural engineer evaluate roof system to determine modifications required to resist <br />uplift and bending forces. Roof span exceeds 40 feet. <br />• Install shutters or other protective systems on unprotected systems windows to exterior doors to <br />meet the SBC Standard SSTD 12-94 of Dade County version of the South Florida Building <br />Code (Section 2314.1, 2314.5 and 1-2314.4). <br />Minor (Please note that while these minor retrofit recommendations will enhance the integrity of <br />shelter space evaluated they will not increase potential usable shelter square footage.) <br />• Remove potential lay -down hazards. <br />• Remove potential debris hazards. <br />BulI,DING <br />BtiILD ING FLOOR AREA <br />USABLE <br />USABLI Sfdmi R <br />I�C1Iv1iiCR <br />(SQUARE FEET) <br />POTENTIA1, <br />(A.RC444a <br />adr��ili <br />Ilt)S`I'/I /i)74- <br />k <br />111.1.13.1t Y <br />i oOTPRINT <br />SHVIAlit AREA <br />AS XS A <br />AREA <br />FT R ) <br />MI <br />/ <br />BUILDING 900 9040 9040 N/A 0 0 9040 <br />SUIITO"I'ALS: <br />TOTALS: N/A 0 0 9040 <br />3 <br />