My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000-337B
CBCC
>
Official Documents
>
2000's
>
2000
>
2000-337B
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/13/2024 12:13:45 PM
Creation date
8/13/2024 11:59:51 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Application
Approved Date
11/07/2000
Control Number
2000-337B
Agenda Item Number
11.B.
Entity Name
State of Florida Department of Community Affairs
Subject
Hazard Mitigation Grant Program Application for Shelter Retrofit Projects
Sebastian Elementary
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7 <br />4i® <br />Marginal characteristics of this facility include: <br />• There is limited exposure to large and small wind-borne debris. <br />• The building has a flat, lightweight roof system. <br />• The building is within the Vulnerability Zone of two Section 302 facilities but has low release <br />potential. <br />Non-compliant characteristic of this facility include: <br />• Several hazards within lay -down range of building. <br />• The building has unprotected windows and doors that lead into shelter areas. <br />The building's roof exceeds a 40 foot span <br />Retrofit Recommendation: <br />Major <br />• Have a structural engineer evaluate roof system to determine modifications required to resist <br />uplift and bending forces. Roof span exceeds 40 feet. <br />• Install shutters or other protective systems on unprotected systems windows to exterior doors to <br />meet the SBC Standard SSTD 12-94 of Dade County version of the South Florida Building <br />Code (Section 2314.1, 2314.5 and 1-2314.4). <br />Minor (Please note that while these minor retrofit recommendations will enhance the integrity of <br />shelter space evaluated they will not increase potential usable shelter square footage.) <br />• Remove potential lay -down hazards. <br />• Remove potential debris hazards. <br />BulI,DING <br />BtiILD ING FLOOR AREA <br />USABLE <br />USABLI Sfdmi R <br />I�C1Iv1iiCR <br />(SQUARE FEET) <br />POTENTIA1, <br />(A.RC444a <br />adr��ili <br />Ilt)S`I'/I /i)74- <br />k <br />111.1.13.1t Y <br />i oOTPRINT <br />SHVIAlit AREA <br />AS XS A <br />AREA <br />FT R ) <br />MI <br />/ <br />BUILDING 900 9040 9040 N/A 0 0 9040 <br />SUIITO"I'ALS: <br />TOTALS: N/A 0 0 9040 <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.