Laserfiche WebLink
Mr. Himanshu Mehta <br />October 18,•2024 <br />Page 2 <br />• Each new well will be equipped with an 8 -inch dual extraction QED well cap. Wellheads that <br />were removed from abandoned wells will be installed on the seven replacement wells and <br />three new vertical wells. <br />• Three new QED AP -4 plus pumps, fittings, and hardware will be installed in the three new <br />vertical wells. Existing pumps that were removed from the abandoned wells will be installed in <br />the seven replacement wells. <br />• Vertical well spoils will be transported to the active work face by SCS -FS. <br />Task Two: HDPE Vacuum Lateral, Air and Forcemain Piping Installation <br />SCS -FS will provide labor equipment and materials to install new HDPE vacuum lateral (SDR -17), air (SDR - <br />9) and forcemain (SDR -11) piping based on the following scope of work description: <br />• Install 280 feet of 6 -inch vacuum lateral, 2 -inch air and 3 -inch forcemain piping from well EW - <br />39 to replacement well EW -56R and tie into the existing piping at EW -55. <br />• Install 360 feet of 6 -inch vacuum lateral, 2 -inch air and 3 -inch force main piping from well EW - <br />40 to well EW -42. <br />• Install the 18 -inch valve that was removed at location ZV-21. Install 560 feet of 18 -inch <br />vacuum lateral, 2 -inch air and 3 -inch force main piping from ZV-21 to the tie in location at SC - <br />5. Vacuum, air and forcemain risers will be installed at replacement wells EW -69, EW -70 and <br />side.slope collectors SC -3 and SC -4. <br />• Install the 24 -inch valve that was removed at location ZV-20. Install 160 feet of 24 -inch <br />vacuum lateral, 2 -inch air and 3 -inch forcemain piping from valve ZV-20 to downslope of SC -1. <br />The 24 -inch vacuum lateral will terminate with a blind flange for future lateral piping. A 24 - <br />inch by 8 -inch tee will be installed prior to the blind flange. <br />• Install 880 feet of 8 -inch vacuum lateral, 2 -inch air, and 3 -inch forcemain piping to side slope <br />collectors SC -1, SC -2, replacement well EW -72 and new wells EW -2401, EW -2402 and EW - <br />2403. <br />Clean fill will be backfilled around all piping. Trench spoils that cannot be backfilled will be <br />transported to the active working face by SCS -FS. <br />ASSUMPTIONS <br />The -scope of work is based on the following assumptions: <br />• At a minimum, SCS -FS will have site access and permission to work Monday through Saturday <br />from*7:00 AM to 7:00 PM. <br />• The scope of work is based on one drill rig mobilization and demobilization. If additional <br />mobilizations are needed there will be an additional cost based on the fee schedule. <br />• Scope of work does not include new include new wellheads. Additional wellheads will be charged <br />based on the fee schedule. <br />• • Piping installation quantities are approximate and may vary. <br />• The work area will be accessible and free of obstructions or other work activities performed by <br />others that could delay the installation process. <br />• SCS -FS may limit or restrict access to any and all traffic adjacent to the work area as needed. <br />• Any additional drug testing or personnel background requirements to work for this project - those <br />costs need to be passed through. Also, consider the time it takes to perform these checks/tests. <br />• Additional change orders may be needed if changes to the scope of work are made after the date <br />of this proposal or if costs due to unforeseen circumstances. <br />• Payment terms to SCS -FS will be NET 30 or less. <br />