Laserfiche WebLink
According to the approved TIA, the existing level of service on impacted roadways would not be <br />lowered by the traffic generated by development of 466,000 square feet of shopping center on the <br />subject property. <br />- Water <br />A retail commercial use of 466,000 square feet on the subject property will have a water <br />consumption rate of 141 Equivalent Residential units (ERU), or 35,250 gallons/day. This is based <br />upon a level of service standard of 250 gallons/ERU/day. Water lines extend to the site from the <br />South County Reverse Osmosis Plant which currently has a remaining capacity of approximately <br />1,866,000 gallons/day and therefore can accommodate the potable water demand associated with the <br />proposed zoning district. <br />- Wastewater <br />The subject property is serviced by the Central Regional Wastewater Treatment Plant. Based upon <br />the most intense use allowed under the proposed amendment, development of the property will have <br />a wastewater generation rate of approximately 141 Equivalent Residential Units (ERU), or 35,250 <br />gallons/day. This is based upon the level of service standard of 250 gallons/ERU/day. The Central <br />Regional. Wastewater Treatment Plant currently has a remaining capacity of approximately 364,000 <br />gallons/day and can accommodate the additional wastewater generated by the proposed zoning <br />district. <br />- Solid Waste <br />Solid waste service includes pick-up by private operators and disposal at the county landfill. For a <br />466,000 square foot commercial development on the subject site, solid waste generation will be <br />approximately 2,351 waste generation units (WGU) annually. A WGU is a Waste Generation Unit <br />measurement equivalent to one ton (2,000 pounds) of solid waste. Using the accepted conversion <br />rate of one cubic yard for every 1,200 pounds of compacted solid waste generated, the 466,000 <br />square feet of commercial development would be expected to generate 3,918 cubic yards of <br />wastelyear. <br />A review of the solid waste capacity for the active segment of the county landfill indicates the <br />availability of more than 840,000 cubic yards. The active segment of the landfill has a 1 year <br />capacity, and the landfill has expansion capacity beyond 2010. Based on staff analysis, it was <br />determined that the county landfill can accommodate the additional solid waste generated by the <br />proposed zoning district. <br />- Drainage <br />All developments are reviewed for compliance with county stormwater regulations which require <br />on-site retention, preservation of floodplain storage and minimum finished floor elevations. In <br />addition, development proposals must meet the discharge requirements of the county Stormwater <br />Management Ordinance. Any development on the subject property will be prohibited from <br />discharging any runoff in excess of the pre -development rate. <br />In this case, the minimum floor elevation level of service standard applies, since the property lies <br />within a floodplain. Consistent with Drainage Policy 1.2, "all new buildings shall have the lowest <br />habitable floor elevation no lower than the elevation of the 100 -year flood elevation as shown on the <br />Federal Emergency Management Agency's Flood Insurance Rate Map, or as defined in a more <br />detailed study report." Additionally, section 930.07(2) of the county's LDRs requires that all <br />development shall have the Iowest floor (including basement) elevated to six inches or more above <br />the base flood level. Since the subject property lies within Flood Zone AE -7, which is a special <br />flood hazard area located within the 100 -year floodplain, any development on this property must <br />have a minimum finished floor elevation of no less than 7.5 feet above mean sea level. <br />Besides the minimum elevation requirement, on-site retention and discharge standards also apply <br />to this request. With the most intense use of this site, the maximum area of impervious surface under <br />the proposed zoning classification will be approximately 32.6 acres. The estimated runoff volume, <br />based on that amount of impervious surface and the 25 year/24 hour design stone, will be <br />approximately 2,154,000 cubic feet. In order to maintain the county's adopted level of service, the <br />applicant will be required to retain approximately 387,000 cubic feet of runoff on-site. With the soil <br />characteristics of the subject property, it is estimated that the pre -development runoff rate is 337.61 <br />cubic feet/second. <br />Based upon staffs analysis, the drainage level of service standards will be met by limiting off-site <br />discharge to its pre -development rate of 337.61 cubic feettsecond, requiring retention of 387,000 <br />cubic feet of runoff for the most intense use of the property, and requiring that all finished floor <br />elevations exceed 7.5 feet above mean sea level. <br />As with all development, a more detailed review will be conducted during the development approval <br />process. <br />APRIL 149 1998 <br />-57- <br />