Laserfiche WebLink
• <br />7. Traffic Circulation: Access to 66' Avenue for all seven tracts will be via the subdivision's <br />roadway, proposed as a single cul-de-sac along the southern boundary of the project. The <br />road will be constructed as a stabilized unpaved road within a 60' private road right-of-way. <br />The LDRs allow such a road to be unpaved, since the subdivision is private, generates less <br />than 100 daily trips, and is located outside the Urban Service Area. The traffic engineering <br />division has reviewed and approved the roadway layout. <br />8. Stormwater Management: The public works department has reviewed and approved a <br />conceptual stormwater plan. A detailed engineering stormwater plan will be reviewed and <br />approved as part of the land development permit or permit waiver process. <br />9. Utilities: The project will have on-site well and septic tanks for each tract. These utility <br />provisions have been approved by the Utility Services and Environmental Health <br />Departments. <br />10. Dedications & Improvements: The existing 66' Avenue right-of-way is currently 50', less <br />than the minimum 60' local roadway requirement. Therefore, 5' of additional 661' Avenue <br />right-of-way is required from the site without compensation. The ultimate road right-of-way <br />width for 661 Avenue is 136'. However, the Public Works Director has indicated that the <br />county does not want to purchase any of the additional 38' of 661h Avenue right-of-way that <br />may ultimately be needed from the site. Prior to the issuance of a land development permit <br />(LDP) or LDP waiver, the applicant shall dedicate without compensation 5' of 661 Avenue <br />right-of-way from the site. <br />Since the proposed development is a low traffic generator/attractor and is outside of the <br />Urban Service Area, the applicant is not required to provide sidewalks or bikeways. <br />11. Concurrency: The applicant has obtained a conditional concurrency certificate which <br />satisfies concurrency requirements related to the special exception use and preliminary PD <br />plan/plat requests. Therefore, all concurrency requirements related to special exception use <br />and preliminary PD plan/plat approval have been satisfied. <br />12. Environmental Issues: Since the site is over 5 acres, the native upland set-aside <br />requirements of section 929.05 potentially could apply. However, based upon an inspection <br />of the site by the county's environmental planning staff, staff has determined that no native <br />upland habitat exist on the site. Therefore, no native upland habitat preservation <br />requirements apply. <br />13. Waivers: The applicant is not requesting any waivers through the PD process. <br />14. Buffers and Setbacks: Given that the surrounding area is presently used for agricultural <br />purposes, no special buffering is. required under the planned development LDRs. Since the <br />A-1 district minimum 30' setback exceeds the 25' perimeter PD setback, the 30'A-1 district <br />setback will control. Although no specific agriculturetresidential buffers apply, the plan <br />proposes a minimum distance of 50' from any building envelope to any adjacent property <br />with an active agricultural operation. <br />The proposed location of the project's roadway creates a situation for double frontage lots <br />for the property immediately south of the project. While LDR section 915.16 does not <br />require a perimeter buffer, a double frontage buffer could be required along the southern <br />boundary if properties south of the road are not allowed to access the road [reference LDR <br />sections 913.09(6)(c)5 and 913.09(3)(c)5]. However, as allowed by LDR section <br />May 12, 1998 <br />45 <br />• <br />