Laserfiche WebLink
r I <br />Local Road Right -of -Way for 15* Street SW. • A portion of 1511 Street SW was platted <br />with Grovenor Estates as a 35' wide half -street. The applicant will either need to <br />dedicate an additional 25' to complete the local road right-of-way for 1511 Street SW <br />or seek to have the right-of-way abandoned. The right-of-way dedication or <br />abandonment will need to occur prior to the issuance of an LDP for the area adjacent <br />to 1511 Street SW. <br />Drainage for Thoroughfare Plan Roads: As part of the PD process, the staff has <br />requested that the applicant provide drainage capacity in the site's lake for the future <br />paving of 1311 Street SW, 1711 Street SW, and the widening of 2711 Avenue. Such an <br />arrangement should result in less future right-of-way acquisition by the county. The <br />applicant has agreed in concept to provide drainage capacity for the paving <br />improvement. The details of the drainage capacity would need to be provided for in <br />a developer's agreement which needs to be approved prior to the issuance of the first <br />land development permit. <br />16. Landscape and Buffering Plan: The conceptual landscape plan meets the criteria of <br />Chapter 926 for conceptual approval. Detailed landscape plans will be submitted with the <br />preliminary PD plan. <br />Staff has recommended that a Type "D" buffer be provided around the entire development <br />except in two areas. The fust area is between 43' Avenue and the proposed clubhouse and <br />maintenance building facility where the staff has recommended a Type "C" with a 6' opaque <br />feature. The applicant's plan notes such a buffer. The second area is along 1711 Street SW <br />and 2711 Avenue adjacent to the multi -family POD. Staff has recommended that a Type "C" <br />buffer be provided along 2711 Avenue from the project entry to 1711 Street SW, and along 1711 <br />Street SW from 2711 Avenue to the proposed stormwater pond. The plan labels the buffer <br />along 2711 Avenue but does not label the buffer along 1711 Street SW. The plan needs to be <br />revised to label the buffer along 1711 Street SW, prior to site plan release. These Type "C" <br />buffers are needed to buffer the proposed multi -family development from adjacent off-site <br />single-family areas. As previously stated, the Planning and Zoning Commission <br />recommends that a Type "C" buffer be provided around the entire project site. In staff s <br />opinion, not all perimeters need a buffer "upgrade" due to provision of the golf course on the <br />perimeter. <br />Golf Course Specific Land Use Criteria: Golf courses are subject to the following specific land <br />use criteria which can be waived or modified through the PD process: <br />1. Golf courses and accessory facilities shall not be interpreted to include freestanding <br />commercial miniature golf courses and/or driving ranges or other unenclosed <br />commercial amusements; <br />Note. The conceptual PD plan demonstrates that the golf course is a conventional <br />golf course, and that the driving range is not freestanding. <br />2. No major accessory use or principal building or structure shall be located closer than <br />one hundred (100) feet to any lot line which abuts a residentially designated property; <br />however, the one hundred (100) foot setback may be reduced to normal zoning <br />ocTosE101 i"Z-5)"'M 6 2 5 <br />-54- <br />