Laserfiche WebLink
• <br />Stormwater Management <br />All developments are reviewed for compliance with county stornrwater regulations which require <br />on-site retention. preservation of floodplain storage and minimum finished floor elevations In <br />addition, development proposals must meet the discharge requirements of the county Stormwater <br />Management Ordinance. The site is located within the R-2 Drainage Basin <br />In this case, the minimum floor elevation level -of -service standards do not apply, since the properties <br />do not lie within a floodplain. However, both the on-site retention and discharge standards apply. <br />With the most intense use of this site under the proposed amendment, the maximum area of <br />impervious surface would be approximately 129,591 square feet, or 2.975 acres. The maximum <br />runoff volume, based on that amount of impervious surface and the 25 year/24 hour design storm <br />would be approximately 105,366 cubic feet. In order to maintain the county's adopted level -of - <br />service the applicant would be required to retain approximately 68,991 cubic feet of runoff on-site. <br />With the soil characteristics of the subject properties, the estimated peak pre -development runoff rate <br />is 9 2 cubic feet/second. <br />Based upon staff's analysis, the drainage level -of -service standards will be met by requiring retention <br />of the 68,991 cubic feet of runoff for the most intense use of the property. As with all development, <br />a more detailed review will be conducted during the development approval process <br />Recreation <br />Recreation concurrency requirements apply only to residential development. Therefore, this <br />comprehensive plan amendment request would not be required to satisfy recreation concurrency <br />requirements. <br />Concurrency Summary <br />Based upon the analysis conducted, staff has determined that all concurrency -mandated facilities, <br />including stormwater management, roads, solid waste, wastewater, and water, have adequate <br />capacity to accommodate the most intense use of the subject properties under the proposed land use <br />designation. Therefore, the concurrency test has been satisfied for the subject request. <br />Compatibility with the Surrounding Area <br />Given the subject property's location, between a residential neighborhood and a middle school, <br />compatibility with the surrounding area is an important concern associated with this request. <br />Although the middle school has a residential designation, the school is a public use. For that reason, <br />the request is for an expansion of an existing use pattern. Although the requested PUB designation <br />allows a variety of uses, the site characteristics indicate that the most likely uses would be public <br />office and service related uses on the north 3.5 acres of the site. Such uses are usually busiest during <br />daytime working hours when many residents are away from home. In contrast to retail uses, office <br />type uses operate during fewer hours, and generate less traffic, noise, and other impacts. <br />Any potential impacts associated with development of the site would most directly affect the <br />residences abutting the site's western boundary However given the rectangular shape of the site <br />and the location of existing streets, buildings on the site are likely to be located towards the eastern <br />portion of the site, away from adjacent residences. Similarly, other "soft" features such as required <br />open space and stomrwater management areas are likely to be located close to the subject property's <br />• <br />January 15, 2002 <br />49 <br />