Laserfiche WebLink
Enhance application and system performance errors as outlined by the operators at both plants. <br /> Estimated Cost (2 x $5,000 = 1610 ,000 - Capacity Charge Fund) $ 101000. 00 <br /> Miscellaneous Computer hardware and periphery upgrades as determined by Computer Services Dept. <br /> (Estimated Cost $25,000 - 50% Capacity Charge Fund / 50% R&R) (In progrrss) <br /> ➢ Contingency at approximately 10% to be utilized as approved by the Director of Utilities. <br /> Total Estimated Cost (rounded) $111 ,700 <br /> Phase Ill. REMOTE SITS : <br /> ➢ Upgrade the current Allen Bradley Radio Telemetry Units (RTU) to Allen Bradley model <br /> Slick-500 (SLC-5/03 units & upgrade communication protocol to Modbus). This <br /> replacement will modernize the system & eliminate obsolete equipment. Modbus protocol is <br /> the preferred method for radio communication , because of its structural simplicity. <br /> A. Roseland Elevated Storage Tank Site equipment replacement. Estimated Cost 510,500 - R& RFund <br /> B . Grand Harbor Re -pump Station system upgrade. Estimated cost 54,'_00 - R&R Fund <br /> C. Gifford Elevated Storage Tank Site system replacement. Estimated cost 510,500 - R& R Fund <br /> D. Kings Highway Elevated Storage Tank Site system replacement. Estimated cost $ 10,500 - R&R Fund <br /> E. Highway 510 / 51 _ Pressure Sranon system. Estimated cost $4,200 - Capacity Charge Fund <br /> F. Sebastian Pressure Monnonng Station. Estimated cost 54,200 - Capacity Charge Fund <br /> Contingency at approximately 1000 to be uniized as approved by the Director of Utilities. <br /> Total Estimated cost (rounded) 548,50o <br /> Total Estimated Project Cost 5207 700110 <br /> RECO '(iMENDATION <br /> The Staff of the Department of Utility Services recommends that the Board of Couatv <br /> Commissioners approve proceeding with Phase III of the project in the authorized amount of <br /> 548 , 500 . It is further requested that the Board of County Commissioners accept / approve Work <br /> Authorizations N0 . 3 in the amount of $44 , 100 , NO . 4 in the amount of 55000 , both from <br /> ROCHA Controls , Inc - , and allow the Chair to execute same . <br /> FUNDING SOURCE <br /> The funding for the total project will come from the Renewal & Replacement (R& R) Funds No . <br /> 471 and Capacity Charge Fund No . 472 . The total estimated R&R budget (Fund No . 471 ) equals <br /> S 107 , 992 , and the total estimated Capacity Charge budget (Fund No . 472) equals 599 , 708 <br /> ON MOTION by Commissioner Stanbridge , <br /> SECONDED by Commissioner Adams , the Board <br /> unanimously approved proceeding with Phase III of <br /> the project in the authorized amount of $ 48 , 500 and <br /> approved Work Authorizations 3 in the amount of <br /> $ 44 , 100 and 4 in the amount of $ 5 , 000 with Rocha <br /> Controls , as recommended by staff. <br /> WORK AUTHORIZATIONS ARE ON FILE <br /> IN THE OFFICE OF THE CLERK TO THE BOARD <br /> NOVEMBER 6 , 2001 <br /> - 95 - <br />