i <br /> 3 . Victaulic type couplings and fittings may be used in lieu of flanged points . <br /> Pipes shall be radius grooved as specified for use with the Victaulic <br /> ' couplings . Flanged adapter connections at fittings, valves , and equipment <br /> shall be Victaulic Vic Flange Style 741 , equal by GustinBacon Group, <br /> Division of Certain-Teed Products, Kansas City, Kansas, or equal . <br /> 4 . Sleeve type couplings shall <br /> Ypbe used with all burred piping . The <br /> ' couplings shall be of steel and shall be Dresser Style 38 , Smith Blair <br /> Style413 , Baker Allsteel, or equal . The coupling shall be provided with <br /> hot dipped galvanized steel bolts and nuts unless indicated otherwise . <br /> ! 5 . All couplings shall be furnished with the pipe stop removed . <br /> 6 . Couplings shall be provided with gaskets of a composition suitable for <br /> exposure to the liquid within a pipe . <br /> 7 . If the Contractor decides to use victaulic couplings in lieu of flanged joints , <br /> he shall be responsible for supplying supports for the joints . <br /> 5 . TAPPING SLEEVES AND VALVES <br /> A . Tapping sleeves shall be long body, mechanical joint type with flanged outlet, ductile <br /> iron construction, split in two sections and designed for assembly around the <br /> main without halting service . The sleeve shall be suitable for use with the type and <br /> O . D . of pipe being tapped. <br /> iB . Tapping ' valves ends shall be a standard flange (for bolting to the sleeve) by <br /> mechanical joint. Valves shall have oversized seat rings to permit entry of the tapping <br /> machine cutters and, except as otherwise specified, shall be similar in construction and <br /> operation to AWWA C509 resilient seated gate valves . Tapping valves and sleeves <br /> shall be cold water pressure rated at 200 psi minimum for valve sizes up to 12 inches <br /> or less and 150 psi minimum for valve size over 12 inches . Tapping sleeves and <br /> valves shall be " Mueller" or approved equal . <br /> 6 . FIRE HYDRANTS <br /> A . Hydrants shall be dry barrel, traffic model , compression type, 5 - 1 /4 inch valve, <br /> opening left, with one 4- 1 /2 inch pumper nozzle and two 2- 1 /2 inch hose nozzles <br /> (National Standards Threads) . Hydrants shall have mechanical joint 6 " inlet <br /> connection and National Standard pentagon operating nut. Hydrants shall be <br /> Kennedy Guardian, model K81 A, Mueller, model A423 or Clow Medallion. <br /> Hydrants shall meet or exceed the requirements of AWWA C502 . All hydrants <br /> shall be painted Federal Safety Yellow - Rustoleum 944 . <br /> Hydrants and associated gate valves shall be connected to the main using <br /> anchoring fittings , or other approved restraining devices , <br /> i <br /> iC : \ Down1oad \ techspec - 02502 . doc SC502 - 2 <br />