My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2004-013.C
CBCC
>
Official Documents
>
2000's
>
2004
>
2004-013.C
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2016 10:05:33 AM
Creation date
9/30/2015 7:14:24 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
01/13/2004
Control Number
2004-013.C
Agenda Item Number
11.I.1
Entity Name
Barth Construction
Subject
North County Regional Park Volume II
Contract and Specifications
Area
North County Regional Park
Project Number
0399
Bid Number
6038
Archived Roll/Disk#
3209
Supplemental fields
SmeadsoftID
3589
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
x, <br /> C . Flushing shall continue until a minimum water volume of two times the aggregate <br /> pipe volume has passed through the pipe section being cleaned. The aggregate pipe <br /> volume shall include all pipe carrying flushing water from the point of introduction <br /> to the work to the point(s) of discharge from the run being cleaned. <br /> D . For nominal pipe sizes of 6 inches and smaller, the pipe shall be flushed through a <br /> discharge extension of at least the full pipe diameter. For nominal pipe sizes greater <br /> than 6 inches, a 6 inch diameter discharge extension pipe, connected to the work with <br /> reducer(s), may be used in lieu of a full diameter blowoff. <br /> 4 <br /> E . Flushing water shall be carried beyond the trench and shall be discharged in a <br /> manner that will not cause erosion nor structural damage on or off-site, and will not <br /> cause contravention of State water quality standards in receiving surface waters . The <br /> Contractor shall provide adequate extension pipe, sedimentation basin(s) , and/or <br /> diffusion devices as necessary to prevent such damage. <br /> 4 . HYDROSTATIC LEAKAGE AND PRESSURE TESTING <br /> A. Hydrostatic pressure and leakage tests for ductile iron pipe shall conform with <br /> Section 4 of AWWA C-600 Specification with the exception that the Contractor shall <br /> furnish all gauges, meters, pressure pumps and other equipment needed to test the <br /> line . P. V . C . pipe shall be tested in accordance with the applicable sections of <br /> AWWA M23 . Upon completion of flushing, the installed pipe system shall be <br /> tested for tightness under a continuous hydrostatic gauge pressure of 25 psi and then <br /> 100 or 150 psi as applicable, ± 5 psi as applicable, determined at the lowest point in <br /> the system, for a period of 2 hours . The allowable leakage rate shall not exceed that <br /> defined in and specified by AWWA C600- 82 or AWWA M23 , <br /> Be If the work is subject to acceptance by a municipal or private utility with its own <br /> adopted test requirements more stringent than those stated herein with regard to <br /> pressure, duration, and/or allowable leakage rate, such requirements shall supersede <br /> these specifications . <br /> C . Testing shall be performed separately on each valved-off section of the installed <br /> system . Testing shall be against closed in-line valves with each valve in the system <br /> subject to the full test pressure differential for full test time at least once during the <br /> course of testing. <br /> D . Allowable leakage shall be calculated based on the pipe diameter(s) and total laid <br /> length of the run being tested, with no additional allowance for fittings , or joints . No <br /> visible leakage shall be allowed . <br /> If visible leakage is noted during the course of testing, or if allowable leakage is <br /> exceeded, such leakage shall be repaired to the satisfaction of the Engineer and the <br /> test repeated or extended for an additional period up to the full test time with suitable <br /> adjustment for previous make-up water used, at the Engineer's discretion. <br /> CAD own 1 oad\techspec-02704.doc <br />