2004-013.C
CBCC
>
Official Documents
>
2000's
>
2004
>
2004-013.C
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2016 10:05:33 AM
Creation date
9/30/2015 7:14:24 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
01/13/2004
Control Number
2004-013.C
Agenda Item Number
11.I.1
Entity Name
Barth Construction
Subject
North County Regional Park Volume II
Contract and Specifications
Area
North County Regional Park
Project Number
0399
Bid Number
6038
Archived Roll/Disk#
3209
Supplemental fields
SmeadsoftID
3589
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
time, the Contractor shall remove the mixture, reshape and recompact the <br /> subgrade, replace the materials removed with additional coquina shell and reshape <br /> and recompact the coquina shell base at no cost to the Owner. <br /> D . If cracks or checks appear in the base which would impair the structural <br /> integrity of the base in the opinion of the Engineer, the Contractor shall <br /> remove the cracks or checks b i <br /> y rescarEying, reshaping, refilling with coquina shell <br /> where necessary, and recompacting at no cost to the Owner. <br /> E . The finished coquina shell base shall be checked for thickness at intervals of not <br /> more than 500 feet. Any areas which are less than 7- 1 /2 inches in thickness shall be <br /> corrected by scarifying and adding rock. The scarifying shall extend for 50 feet <br /> either side of the deficient area. Areas which are less than 1 /2 inch deficient in <br /> thickness shall be corrected if the Engineer determines that the area is extensive or <br /> may adversely affect the quality of the finished work . <br /> 6. PRIME COAT <br /> A. The prime coat shall be a rapid curing liquid cut back asphalt equal or <br /> equivalent to RC-70 or RC -250 at the Contractor's option, and conforming to <br /> Sections 300 and 916-2 of the 1991 Edition of the Florida D . O . T. Standard <br /> Specifications for Road and Bridge Construction, <br /> B . The surface of the base material shall be cleaned after final compaction and the <br /> moisture content of the base shall not exceed 90 percent of the optimum moisture <br /> before the prime coat is applied. The prime coat shall be applied uniformly with a <br /> pressure distributor. The entire length of the spray bar shall be set at the height <br /> above the surface recommended by the Manufacturer for even distribution. The <br /> prime coat shall be applied to the finished base course at the rate of 0 . 15 gallons per <br /> square yard at a temperature between 100° F. t° 1110 F . The prime coat shall be <br /> applied such that a period of no longer than two (2) hours lapse prior to <br /> application of the asphaltic concrete wearing course, unless the prime coat is covered <br /> with sand or screenings as outlined in Section 300-6 . 5 of the 1991 Edition of the <br /> Florida D . O . T. Specifications. <br /> 7. TESTING <br /> A . The maximum density and optimum moisture shall be determined in <br /> accordance with the Modified Proctor Test procedures of ASTM-D1557 or <br /> AASHTO-T180 (Method D) . The percentage compaction and in-place <br /> density shall be determined according to procedures of ASTM-D „ <br /> 2167 Test for <br /> Density of Soil In-Place by the Rubber Balloon Method " or the nuclear method <br /> ASTM- D2922 . In general , one Modified Proctor Test per 500 lineal feet of <br /> roadwork shall be performed on a representative sample of base material from <br /> location(s) designated by the Engineer. In-place density testing shall be <br /> performed at the rate of one test per 500 lineal feet of roadwork at comparable <br /> locations unless otherwise specified by the Engineer. <br /> C :\DON7lload\techspec-02304 .doc 02304-2 <br />