Laserfiche WebLink
Peter <br /> • I UUM0 <br /> IRIEP 0. BfNWXL9X91AVLT0iY. LYC. <br /> Indian River County Jail Expansion <br /> Medical/Infirmary Addition & Renovation <br /> June 28 , 2006 <br /> 11A Detention Equipment <br /> 11A- 1 . Detention equipment package is included as follows : <br /> a . Commercial and security hollow metal doors and frames <br /> b . Security and builders door hardware <br /> c. Security glass <br /> d . Electronic security including ( 14) hi-resolution color cameras , (9) hi-resolution <br /> cameras , (2) 16-channel video servers, (6) duress switches and ( 1 ) Proximity <br /> card reader. <br /> 11A-2 . The cost for door controls and door position switches are not included . <br /> 11A-3 . A six-zone Fiber Optic Fence Monitoring System is included for the new <br /> perimeter fencing . The system will consist of five 400 , foot zones and one 600 <br /> foot zone . A fence processor at the New 256-Bed Dormitory will communicate <br /> and be graphically displayed on the Touchscreen control panel at the Central <br /> and/or Pod C control room . <br /> 15A Fire Sprinkler System <br /> 15A- 1 . No clarifications at this time. <br /> 15B Plumbing <br /> 15131- 1 . The cost for relocating the existing 500 gallon fuel tank' is included . The cost to <br /> drain the tank prior to removal or to fill the fuel tank after relocation is not <br /> included . <br /> 15B-2 . It is assumed that the existing diesel fuel lines to the fuel tank are double-wall <br /> and can be abandoned in place. New double wall piping will be installed from the <br /> relocated fuel tank to the connection point of the existing piping . The relocation <br /> of the tank and piping is included as an Allowance until further design and <br /> permitting information is available . <br /> 15B-3. Medical gas certifications are not included for the vacuum and compressed air <br /> lines at room 209 Dental Lab. <br /> 15C HVAC Systems <br /> 15C- 1 . HVAC Test and balance is included for new ductwork and diffusers only . <br /> 16A Electrical Systems <br /> 16A- 1 . The cost for the Nurse Call System is not included . ' <br /> 16A-2 . The cost for security conduits and back-boxes indicated on sheet SE1 . 14 is <br /> included . Additional security conduits, back-boxes , door controls and position <br /> switches not indicated on sheet SE1 . 14 are not included . <br /> 16A-3 . The cost for removing the existing light pole indicated on sheet C1 . 2 is included . <br /> Page 6 of 7 <br /> MA2006 Projects\IRC Jail\Infirmary\ESTIMATE SUBMITTAL DOCUMENTS\IRCJ Infirmary Clarifications r2.doc <br />