My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2007-259(a-b)
CBCC
>
Official Documents
>
2000's
>
2007
>
2007-259(a-b)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/14/2016 10:18:20 AM
Creation date
9/30/2015 11:01:50 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Certificate
Approved Date
07/26/2007
Control Number
2007-259(a-b)
Agenda Item Number
county administrator signature
Entity Name
Turner Construction
Subject
IRC Emergency Operations Center - Punch List
Area
4225 43rd Ave.
Project Number
5054.18
Supplemental fields
SmeadsoftID
6484
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Indian River County Emergency Operations Center <br /> Interior Punch List - Tuesday - 06/ 12/07 <br /> June 22. 2007 <br /> Page 16 <br /> ESF-8 -Room 026 (continued) <br /> 3 . South wall left inside corner bottom corner needs to be repainted and also above the vinyl base at this area <br /> drywall needs to be repainted. <br /> 4. South wall vinyl base is not adhered completely to the drywall . <br /> 5 . To the left of door frame 026, drywall needs to be repainted where the door frame paint has gotten on the <br /> drywall. <br /> 6. One ceiling tile not in place. <br /> 7 . Data outlet on the east wall has not been secured to the junction box. <br /> ESF-7- Room 027 & ESF-6 - Room 028 <br /> 1 . Drywall to the left of door frame 027 is irregular needs to be sanded and repainted. <br /> 2. West wall to the left of Door 027 , the west wall adjacent to Room 029, drywall around the electrical outlet <br /> cover needs to be sanded and repainted. That is also true about the drywall around TC Outlet 30. <br /> 3 . South wall , left inside corner needs to be sanded and repainted and also drywall above the vinyl base on the <br /> south wall to the right of this inside corner needs to be cleaned of vinyl base adhesive. <br /> 4. East wall, center of the wall needs to be cleaned of dirt and debris. <br /> 5 . Drywall around electrical outlet needs to be sanded and repainted. Irregular. <br /> 6. Drywall above the vinyl base to the bottom right Data Outlet 37/38B needs to be patched and repaired and <br /> repainted. <br /> 7. Southwest outside corner that is the southwest corner adjacent to Room 028 needs to be sanded and repainted. <br /> 8. East wall, to the right of Door 027 marks on the drywall above the door stop needs to be patched and repaired. <br /> That is also true above the vinyl base on the south end of the wall. <br /> 9. Right inside corner to the right of Door 027 needs to be sanded and repainted. Very irregular. <br /> 10. Carpet at the southeast outside corner of Room 029 needs to be secured to the floor, at this time it is not. <br /> 11 . Floor boxes are not installed at this time. <br /> ESF-5 - Room 029 <br /> 1 . Bottom left of door frame 029, dent in the frame, this needs to be repaired. <br /> 2 . Bottom right of Door 029 drywall is irregular, needs to be sanded and repainted. <br /> 3 . West wall, left inside corner needs to be sanded and repainted . Drywall irregular. That is also true of drywall <br /> around electrical outlet on this wall . <br /> 4. One ceiling tile not in place. <br /> 5 . South wall, 2nd full ceiling tile off the west wall tile is damaged. <br /> ESF-4 - Room 030 <br /> 1 . Outside face of Door 030 glue below the lockset needs to be removed. <br /> 2. Inside corner to the right of Door 030 drywall is irregular above the vinyl base needs to be sanded and <br /> repainted. <br /> 3 . South wall, drywall to the right of the electrical outlet marks on the drywall need to be cleaned and repainted. <br /> 4. Right inside comer of the south wall needs to be sanded and repainted. Drywall is irregular. That is also true <br /> of the drywall leading into this comer at this same location . <br /> 5. Drywall to the left of TV Outlet 18 needs to be sanded and repainted. <br /> 6. Drywall to the top left of Data Outlet 25126C needs to be repainted. <br /> 7. West wall, the right inside comer approximately up 2-3ft. needs to be sanded and repainted. Irregularities in <br /> the corner. <br /> 8. North wall between electrical outlet and the left inside corner the drywall above the vinyl base needs to be <br /> repainted. <br /> 9. North wall „ marks on the drywall to the upper right of Data Outlet 27/28C . <br /> D O N A D I O <br /> & Associates, Architects, P.A. <br />
The URL can be used to link to this page
Your browser does not support the video tag.