My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2007-259(a-b)
CBCC
>
Official Documents
>
2000's
>
2007
>
2007-259(a-b)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/14/2016 10:18:20 AM
Creation date
9/30/2015 11:01:50 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Certificate
Approved Date
07/26/2007
Control Number
2007-259(a-b)
Agenda Item Number
county administrator signature
Entity Name
Turner Construction
Subject
IRC Emergency Operations Center - Punch List
Area
4225 43rd Ave.
Project Number
5054.18
Supplemental fields
SmeadsoftID
6484
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Indian River County Emergency Operations Center <br /> Interior Punch List - Tuesday - 06/12/07 <br /> June 22, 2007 <br /> Page 15 <br /> Corridor 024 (continued) <br /> 4. Middle of the wall to the right of Door 023B mark on the drywall needs to be patched and repaired. <br /> 5 . Outsides corners of door opening 024 needs to be sanded and repainted. <br /> 6. Carpeting does not extend fully to the threshold, needs to be corrected. Also, carpeting in this area needs to <br /> be cleaned of dirt and debris, drywall mud and dust in the area of Door 024. <br /> 7. Top right face of hollow metal door frame 024 needs to be sanded and repainted. Finish is very irregular. <br /> 8 . Paint needs to be removed from the weather stripping and the weather strip frame that goes around the door. <br /> 9 . Drywall opening, right and left metal jamb to Door 024 is very irregular, not plumb. This needs to be looked <br /> at not acceptable. <br /> 10. To the right of Door 024, drywall above vinyl base needs to be cleaned of dirt, debris, sanded and repainted <br /> where it is irregular. <br /> 11 . West wall, south inside corner just to the right, irregularities in the drywall need to be sanded and repainted. <br /> 12. Drywall above the vinyl base, approximately 6ft. off the south inside corner and 12ft. off the south inside <br /> comer, irregularities in the drywall need to be sanded and repainted. <br /> 13 . Drywall above the Johnson Control Unit, approximately 3ft., fingerprints on the wall needs to be repainted. <br /> 14. Carpet at the intersection of Corridor 024 & 025 , stains in the carpet this needs to be corrected. Also, the <br /> carpet color between the Corridors and the Multi-Purpose Room do not match. This needs to be looked at and <br /> corrected if possible. <br /> 15 . Two ceiling tiles not in place in this area. <br /> 16. Ceiling grid above Door 024 is unacceptable, ceiling tile not setting flush. Grid needs to be set level off the <br /> drywall . <br /> 17 . Ceiling grid does not set flush to the west wall, needs to be corrected. <br /> Corridor 025 <br /> 1 . Top right of Door 026, drywall needs to be repainted. Fingerprints above the header of the door frame and to <br /> the right of the door frame at the outside edge of the drywall. <br /> 2. Bottom right of Door 026 above the vinyl base drywall, needs to be repainted. <br /> 3. East wall, to the left of Door 027, drywall needs to be repainted above the vinyl base in numerous locations <br /> and also below the Johnson Control Unit. <br /> 4. Drywall to the top left of Door 028, marks on the drywall needs to be repainted and that also true of both door <br /> frame 027 . <br /> 5 . To the right of door frame 029, marks on the drywall and the outside corner at this location needs to be <br /> sanded and repainted. <br /> 6. Left inside comer of Door 030 needs to be sanded and repainted . That is also true of the drywall above the <br /> vinyl base between the outside and the inside corner to the left of Door 030. <br /> 7 . Outside corner, to the right of Door 030, needs to be sanded and repainted. <br /> 8 . North wall to the left of electrical outlet, drywall is irregular, needs to be sanded and repainted . Also, drywall <br /> around the electrical outlet is irregular needs to be sanded and repainted. That is to the left of the outlet, <br /> around the outlet and to the bottom right of the outlet. <br /> 9. Center of this north wall above the vinyl base drywall is irregular and dents in the drywall needs to be sanded <br /> and repainted. Also, joint in the vinyl base is unacceptable at this area. <br /> 10. Ceiling grid just to the left of the A/C grille is damaged, chipped, needs to be cleaned and replaced. <br /> ESF-S -Room 026 <br /> 1 . Outside face of Door 026 scratches on the door below the lockset the complete width of the door and also dirt <br /> and fingerprints at the hinge side opposite the view light. <br /> 2. To the right of Door 026 bottom right drywall is cracked needs to be patched and repaired . <br /> D O N A D I O <br /> & Associates, Architects, P.A. <br />
The URL can be used to link to this page
Your browser does not support the video tag.