Subject
IRC Emergency Operations Center - Punch List
Area
4225 43rd Ave.
Project Number
5054.18
Supplemental fields
SmeadsoftID
6484
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Indian River County Emergency Operations Center <br /> Interior Punch List - Friday - 06/ 15/07 <br /> June 22, 2007 <br /> Page 3 <br /> Storaee Room 044 <br /> 1 . Corridor side of door face 044 needs to be cleaned of glue and scratch marks, and also red marker throughout <br /> the whole face of the door. <br /> 2. Strike side of door above the lockset needs to be cleaned of paint and also chip on the inside edges of door, <br /> needs to be patched and repaired. <br /> 3 . South wall, left inside corner needs to be sanded and repainted above the vinyl base and also drywall needs to <br /> repainted. <br /> 4. Electrical Data Outlet 13AD & 14AD drywall needs to be sanded and repainted around the perimeter. <br /> 5 . Scuff marks, vinyl base glue, stains, etc, on the walls need to be cleaned and repainted where they occur, <br /> especially along the west wall above the vinyl base and the north wall . <br /> 6. Vinyl tile needs to be cleaned of scuff marks, dirt, etc . and adhesive. <br /> 7 . Vinyl tile is cut too short along the west wall near the electrical outlet. <br /> ESF-911 - Room 045 <br /> 1 . Door 045 , corridor side needs to be cleaned of dirt, glue, etc . <br /> 2. Drywall to the left of hollow metal door frame 045 at the middle hinge needs to be sanded and repainted, <br /> drywall is irregular. Also, adjacent to the lower left hand side drywall is irregular needs to be sanded and <br /> repainted. <br /> 3 . South wall drywall around electrical outlet needs to be sanded and repainted. Also, south wall at the boxed <br /> out Column A4 needs to be cleaned of drywall dust all over the vinyl base and the carpeting. Outside corners <br /> need to be sanded and repainted. Drywall above the vinyl base has a bow in it, needs to be corrected. <br /> 4. East wall drywall around the electrical outlet cover needs to be sanded and repainted around it and below it. <br /> Marks in the drywall , irregularities , etc . Also, painters tape needs to be removed from electrical outlet and <br /> data covers. <br /> 5. South wall between electrical outlet and the right inside corner, gouges in the drywall needs to be patched and <br /> repaired. <br /> 6. Left inside corner, south wall needs to be sanded and repainted above the vinyl base. <br /> 7. North wall to the bottom right of the data outlet and to the bottom left of the electrical outlet above the vinyl <br /> base drywall is irregular needs to be sanded and repainted. Also, drywall around data outlet and electrical <br /> outlet needs to be sanded and repainted, drywall is irregular. <br /> 8 . North wall, left inside corner above the vinyl base, approximately 18-24 inches need to be sanded and <br /> repainted. Very irregular. <br /> 9. West wall , to the left of the right inside corner drywall needs to be sanded and repainted above the vinyl base . <br /> Also, on this wall electrical outlet cover plate needs to be set flush to the drywall. <br /> 10. Fingerprints, dirt marks, stains, etc . need to be cleaned and repainted where they occur, especially on the <br /> north wall directly above the electrical outlet approximately 6ft. high and to the right approximately 3ft. high. <br /> 11 . At this time one light fixture is open, appears to being worked on. <br /> 12. Ceiling grid at the center of the room off the north wall to the right of the westernmost light fixture, grid is cut <br /> too short, the 3" grid off the north wall, this needs to be replaced . <br /> 13. The 2n1 ceiling grid off the west wall in front and between the return air grille and the 2x2 light fixture finish <br /> is damaged on the grid . <br /> EMD SA - Room 047 <br /> 1 . Bottom left of Door 048 , drywall on the outside face needs to be sanded and repainted above the vinyl base <br /> and also nicks on the drywall in this area need to be corrected. <br /> 2. Vinyl base needs to be set tight to the hollow metal door frame at Door 048 and 049. <br /> D O N A D I O <br /> & Associates , Architects, P.A. <br />