Subject
IRC Emergency Operations Center - Punch List
Area
4225 43rd Ave.
Project Number
5054.18
Supplemental fields
SmeadsoftID
6484
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Indian River County Emergency Operations Center <br /> Interior Punch List - Friday - 06/15/07 <br /> June 22, 2007 <br /> Page 4 <br /> EMD SA - Room 047 (continued) <br /> 3 . To the left of hollow metal Door 048 at the bottom left above the vinyl base drywall needs to be sanded and <br /> repainted and also on other areas along the vinyl base between door frame 048 and left inside corner which is <br /> to the right of door 049. <br /> 4. To the right of hollow metal door frame 049, drywall where it abuts the hollow metal frame needs to be <br /> sanded, caulked and repainted the complete length. <br /> 5 . South wall above the vinyl base to the bottom right of the electrical outlet and to the left of Door 049 needs to <br /> be sanded and repainted. Damaged drywall and also vinyl base adhesive needs to be removed from the wall. <br /> 6. Drywall around Data Outlet 7 & 8B and around the duplex electrical and quad outlets needs to be sanded and <br /> repainted. <br /> 7. South wall ceiling grid is unacceptable, it is a double ceiling grid with no tile between the two grids, this <br /> needs to be corrected and Fixed. Unacceptable . <br /> Production / Storage Room 048 <br /> 1 . This room is locked at this time. Unable to access. <br /> EMD Room 049 <br /> 1 . Outside face of Door 049 on the hinge side, scratches in the door finish. <br /> 2 . Carpet needs to be cut tight to the hollow metal door frame and secured to the floor. <br /> 3 . Electrical outlet on the west wall drywall around this outlet needs to be sanded and repainted. Drywall is very <br /> irregular, unacceptable. <br /> 4. West wall between the electrical outlet and Door 050B large irregularity in the drywall behind the vinyl base, <br /> this is unacceptable needs to be corrected and base reapplied. <br /> 5. South wall, drywall around electrical outlet needs to be sanded and repainted. Also, to the left of the electrical <br /> outlet and to the right of the left inside corner glue on the drywall needs to be removed and repainted. <br /> 6. Drywall around electrical outlet cover adjacent to TV Outlet #9 on the south wall needs to be sanded around <br /> the edges of the cover. <br /> 7 . West wall, drywall around duplex outlet and Data Outlet 9/10B needs to be sanded and repainted, irregular. <br /> Also, to the left of the electrical outlet above the vinyl base same condition, irregularity in the drywall. <br /> 8. Left inside corner the southwest comer of the east wall drywall needs to be sanded, caulked and repainted. <br /> 9. North wall , drywall around Data Outlet 5/613 and electrical outlet needs to be sanded and repainted, irregular <br /> at drywall. <br /> 10. Fingerprints, dirt, scuff marks on the vinyl base all need to be cleaned where they occur. <br /> 11 . Ceiling tile needs to be set flush in the grid and no edges exposed. Tile is cut short needs to be replaced . <br /> 12. Ceiling tile above Door 050B appears to be cut short, needs to be adjusted to set flush in the grid or be <br /> replaced. <br /> 13. Ceiling tile at the center of the north wall, the 4 h full ceiling tile off the west wall to the right of Door 050, <br /> needs to set flush in the grid or be replaced. Also, grid in this area is very irregular, uneven needs to be <br /> repaired about the center of the wall. <br /> EMD Conference Room 050 <br /> 1 . Bottom edge of Door 050B, facing the EMD Room 049, full of glue needs to be removed. That is also true <br /> above the lockset glue and paint on the door finish. <br /> 2. To the left of Door 050B , on the EMD side Room 049, vinyl base not secured to the wall or cut tight to the <br /> hollow metal door frame. <br /> 3 . Recessed ceiling can lights in this room are not operable at this time. <br /> 4. Bottom left of hollow metal door frame 050B needs to be painted just above the carpet. <br /> 5 . Drywall around TV Outlet 8 and electrical outlet in this location needs to be sanded and repainted. <br /> D O N A D I O <br /> & Associates, Architects, P.A. <br />