4W <br /> Minimum bedding depth to be 18" and minimum width to be diameter of <br /> pipe . Cost of removal of unsuitable material beneath 18" bedding shall be <br /> paid for as subsoil excavation ( Earthwork) Item No . 5 . <br /> The work under this section shall include all materials , excavation , <br /> backfilling , tamping and disposal of surplus material . All required sheeting <br /> is to be included in the cost of pipe . Such price and payment shall be full <br /> compensation for all work in this section . The work specified in this item <br /> r <br /> shall conform to Section 430 and 443 . <br /> Payment shall be made under: <br /> .. Item No . 32 -Concrete Pipe Culvert ( Perforated 48 " x 76 - Per Linear Foot <br /> Item No . 33 -Concrete Pipe Culvert (48 " x 76 " ) - Per Linear Foot <br /> ow B . CONCRETE PIPE JOINTS : Subarticle 430-7 . 1 . 1 ( Page 384 ) is modified <br /> by the addition of the following : In addition to the rubber gaskets all round <br /> and elliptical concrete pipe other than side drains shall have wrapped filter <br /> fabric jacket joints . The joint between the pipe and the structure shall also <br /> have a filter fabric jacket . These joints shall conform to INDEX 280 and <br /> have a minimum wrapping width of 1 foot on both sides of the exposed <br /> AW joint . The fabric must be long enough to overlap the outer circumference <br /> of the pipe joint by a minimum of 1 foot . Metal strapping will be used on <br /> both sides of the circumference of the pipe joint to secure the fabric . <br /> 40 Other methods which will secure the fabric against the wall until the <br /> backfill is compacted will be considered for approval by the Engineer. The <br /> filter fabric shall be in accordance with Section 985 , and/or as modified by <br /> 4W these special provision , for subsurface drainage . Payment shall be made <br /> under the unit price for concrete pipe . <br /> C . PIPE CULVERTS AND STORM SEWERS : Subarticle 430- 12 . 1 The text <br /> 10 <br /> is deleted and the following substituted : <br /> "The quantities of pipe culvert to be paid for under this Section shall be the <br /> "' plan quantity in feet of concrete Pipe Culvert . Any additions or deletions <br /> thereto , as authorized by the Engineer, shall be determined by plan <br /> dimensions , final measurement , or any combination thereof, as measured <br /> 40 along the centerline of the completed and accepted pipe . " <br /> Pipe that has been patched significantly prior to delivery shall be grounds <br /> 4W for rejection of pipe . <br /> Lifting holes on pipe culverts shall be grounds for rejection of pipe . ASTM <br /> AW Specification C-76-85A and AASTM Specification M170-89 are modified <br /> by the following : <br /> Significant patching of pipe prior to delivery shall be grounds for rejection <br /> of pipe . <br /> The exposure of the ends of the longitudinal stirrups or spacers that have <br /> been used to position the cages during the placement of the concrete may <br /> be a cause for rejection by the Project Engineer. <br /> TECHNICIAL PROVISION <br /> TP - 14 <br />