Entity Name
L.H.Tanner Construction
Subject
Indian River Drive South Sidewalk Improvements
Area
Indian River Drive
Project Number
0201
Bid Number
2007027
Supplemental fields
SmeadsoftID
6065
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
208
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.. E . Earthwork and Backfill <br /> Compaction - All fill must be compacted by hand tamping from under the <br /> pipe up to the center-line . Backfill shall be compacted in 6" lifts up to the <br /> surface to achieve a minimum compaction of 98 percent of maximum <br /> density in roadways and shoulders and 95 percent in easements , in <br /> accordance with AASATO T- 180 and D-2167 . <br />,. F . Ductile Iron Pipe and Fittings <br /> 1 . General <br /> All buried ductile iron pipe shall be manufactured in accordance with <br /> AWWA Specification C- 151 and shall be Class 52 minimum . All <br />.. exposed ductile iron pipe shall be Class 53 minimum . <br /> 2 . Fittings <br /> All underground fittings shall be either bell and spigot, or mechanical <br /> joint. Mechanical joints shall conform to AWWA specification C110 <br /> (ANSI 21 . 10-87) , or latest revision . All exposed aboveground fittings <br /> shall be flanged joint . <br />+` 3 . Bell and Spigot Connections <br /> Joints in bell and spigot pipe shall be push-on , mechanical , or <br /> restrained joints in accordance with AWWA Standard C- 111 (ANSI <br /> 21 . 11 -85) , or latest revision . Mechanical joint pipe set-screw type <br /> retainer glands will not be permitted . <br /> 4 . Flanged Connections <br /> Flanged pipe with screwed-on flanges shall be furnished with long <br /> hubs , and the flanges shall be screwed on the threaded end of the <br /> pipe in the shop , and the face of the flange and end of pipe refaced <br /> together. There shall be no leakage through the pipe threads and the <br /> flanges shall be designed to prevent corrosion of the threads from <br /> outside. The back of the hub shall be caulked where the hub threads <br /> joint with the pipe. <br /> G. Disinfecting Potable Water Pipelines <br /> Before being placed in service , all potable water pipelines shall be <br /> chlorinated in accordance with the latest edition of AWWA C-651 , <br /> "Standard Procedure for Disinfecting Water Mains" , except that the use of <br /> tablets is strictly prohibited . The procedure shall be approved by the <br /> Engineer. The location of the chlorination and sampling points will be as <br /> specified by the Florida Department of Environmental Protection , Water <br /> Distribution System Permit. Taps for chlorination and sampling shall be <br /> uncovered and backfilled by the Contractor, as required . <br /> TECHNICIAL PROVISIONS <br /> r <br />
The URL can be used to link to this page
Your browser does not support the video tag.