My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2004-048
CBCC
>
Official Documents
>
2000's
>
2004
>
2004-048
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2016 10:18:08 AM
Creation date
9/30/2015 7:22:14 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Agreement
Approved Date
03/09/2004
Control Number
2004-048
Agenda Item Number
12.C.
Entity Name
Access Now Inc., Roland Grady, Los Angeles Dodgers Inc.
Dodgertown Inc., Harrison Conference Services of Florida
Subject
Settlement Agreement
Archived Roll/Disk#
3209
Supplemental fields
SmeadsoftID
3658
Document Relationships
10/19/2004
(Attachments)
Path:
\Meetings\2000's\2004
2004-033
(Attachment)
Path:
\Resolutions\2000's\2004
2004-052
(Attachment)
Path:
\Official Documents\2000's\2004
2004-152
(Message)
Path:
\Official Documents\2000's\2004
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FOR SETTLEMENT PURPOSES ONLY <br /> Fac1IW. Dodgertown Vero beach, Florida Accessibility Evaluation Sutvey & Proposed Resolutions Report <br /> FINAL VERSION <br /> sem <br /> Building/section Are* Issue ADAAG Noted Proposed Resolution <br /> Code <br /> ReterenCe+ Photo Result of Experts Discussions <br /> Ref. <br /> 7, Sladium "Cullet Room. The publk fofkf rooms are W"Ished et 4.30 .4 6 install ADAAG compliant <br /> By Main Boys and Got the doors are blocked tactile signago at entry. <br /> Entry open. The doors hove signage on the 4 .30. 5 <br /> doors. 4.30.6 <br /> R. Stadium Mens Toiler The door has knobbed hardwire. TWO 4.13 .9 70 8, 91 100 Change door knobs to lever <br /> Ronin By are three lodet staffs and three lavalones. 11 handles, <br /> Main Entry M the iomat stag Mar hes d grab bar, the 4 . 17.3 <br /> Gate East Combine 2 of the 3 water <br /> Side IOget sfeu is JO inches M width: the depth Figure closet stalls to create an <br /> is 56 inches. The water cbwf Is floor 30(a) accessible stall almllor to an <br /> molrntad. The water doset is 18 inl W ADAAG 30(a) with sidefrear <br /> off the side wag. The toilet beat cover 4.16.2 <br /> dispenser k 60 inches above ft Aber. wall grab bars and toilet <br /> The t000 3180 door operang width is 20 Figure 30 paper and sent cover <br /> inches. The IMnats are 2J inches, 23 427 - 2 dispensers within accessible <br /> Inches, 23 inebes, 23 inches, IJ reach range. Water Closet <br /> inches, 22 Inches, 23 inches, and the Figure 4 can remain as Is, centered at <br /> bat urinal is 23 Inches in heipM from approximately 16 lit" off side <br /> the Snish*d Boor. (1) The #*Mris 4 . 27 .3 wall . Install s coat hook at <br /> kicatedat 43 inches above ft fmithed Figure 5 48"h. <br /> flow. The bvafones are baskaffy 31 or 6 Stall depth can remain at 56 <br /> inches to Me top; 27 inches to the 114", but staff door should be <br /> bottom. The lavatories have a pedestal 4 . 13. 5 made 38" wide. <br /> base: can not get underneath the Figure 30 <br /> favatorles. The krvalorypipet stick out a Modify/change one lavatory <br /> dimension of 9 inches. AN the faucets are 4 , 18,2 to have 2T" high x 6" deep <br /> knobbed. There is a piper tower knee clearance, paper <br /> dowser 4. 19-6 towellsoap dispenser <br /> stag at 48 inches atf to Mie control. 118 M Figure 31 controls at 46" high <br /> the path of travel and would be defined maximum, an accessible <br /> as apmnudmgobject The paper Oliva! 4.192 faucet, and insulated pipes, <br /> dowser sticks out 9 inches and the <br /> boltorn is located 36 inches adore Me Figure 31 Add a Full length mirror and <br /> floor Th* blush control on tin urinals: relocate paper towel <br /> May arc of 41 Inches from be finished 4 . 194 dlapenser, <br /> floor (s) The coat hooks wtfhin the toilet 4. 19.5 One urinal will be lowered to <br /> stag we of 68 inches. TM entry door 17"h maximum to the lip and <br /> threshold nods to have here gap to be 4 27. 3 44" to the flush valve if the <br /> aged in between the concrete slabs. Figure 5 cost of doing so does not <br /> or exceed $1 ,500. Defendant <br /> 6427.2 will explore possible lower <br /> cost options such as <br /> 4.4 . 1 selecting the urinal closest to <br /> Figure 8 the vent stack. <br /> 4. 18.4 <br /> 4 .2 . 5 or <br /> 4.2.6 <br /> Figure 5 <br /> or 6 <br /> 4 . 5. 2 <br /> Page 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.