SECTION 02250 <br /> BORING AND JACKING <br /> PART 1 - GENERAL <br /> 1 . 1 SCOPE <br /> A . Provide all labor, materials , equipment , supervision and incidentals required to <br /> furnish and install casing pipe and carrier pipe as shown on the Plans or specified <br /> ' herein . <br /> B . Related Work Specified Elsewhere : <br /> 1 . Section 01541 , Protection of the Work and Property <br /> 2 . Section 02040 , Demolitions <br /> 3 . Section 02220 , Excavation and Backfill <br /> ' 4 . Section 02230 , Grading <br /> 1 . 2 QUALITY ASSURANCE <br /> A . Installer' s Qualifications and Experience : <br /> 1 . Installer shall be a specialist in the construction of casing pipes by boring and <br /> jacking , and shall have at least five years experience in this specialty. Installer <br /> shall have satisfactorily constructed completely in his own name , during the past <br /> five years not less than ten similar installations which are comparable in <br /> diameter and length to that shown and specified herein . <br /> 2 . Use only personnel thoroughly trained and experienced in the skills required . <br /> The field supervisor of boring operations and the boring machine operator shall <br /> have not less than 12 months experience in the operations of the equipment <br /> being used . <br /> 3 . Welds shall be made only by welders , tackers and welding operators who have <br /> ibeen previously qualified by tests as prescribed in American Welding Society , <br /> AWS DAA to perform the type of work required . Show proof of current <br /> certification when requested . Certification shall not be more than 6 months old <br /> ' from the date the Work is to be performed . <br /> ' B . Requirements of Regulatory Agencies : <br /> 1 . The OWNER has obtained permission from the applicable authorities for <br /> locating the pipeline under the facilities . The CONTRACTOR shall comply with <br /> all provisions of these permits at his own expense . All casing installations shall <br /> ' be as required by the Florida East Coast Railway Company , L . L . C . ( FEC ) , One <br /> Magnolia Street , St . Augustine , Florida 32804 , (904 ) 826-2269 . Refer to <br /> Appendix A for additional requirements (see "General Specifications for Sub- <br /> Grade and Above Grade Utility Crossings of Railroad ' s Right-of-Way" ) . In the <br /> Last revised 8/30/02 02250- 1 EAST GIFFORD <br />