2009-183
CBCC
>
Official Documents
>
2000's
>
2009
>
2009-183
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2016 9:55:32 AM
Creation date
10/1/2015 3:40:36 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Change Order
Approved Date
06/23/2009
Control Number
2009-183
Agenda Item Number
8.H.
Entity Name
FPL Energy Services Inc.
Subject
Change Order No.1 Phase 1 HVAC Improvements
Revised Energy Savings Guarantee
Area
North County Library
Supplemental fields
SmeadsoftID
10718
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ATTACHMENT 7 <br /> Summary of Measurement and Verification Options <br /> All the methods in the FEMP/ IPMVP Guideline for determining savings are based on the same concept, <br /> namely , those energy savings are derived by comparing energy usage after a retrofit to the baseline . It <br /> is <br /> relatively easy to measure post- retrofit consumption ; however, it is impossible to " measure" what the energy <br /> usage would be without the retrofit . Therefore , it is impossible to " measure " energy savings . <br /> Energy savings can only be determined based on assumptions about the baseline . Four options <br /> are <br /> provided to determine energy savings . A particular option is chosen based on the on project- <br />specific <br /> features of each performance contract. <br /> The options differ in their approach to the level and duration of the retrofit verification measurements . <br /> For <br /> instance , Options A and B both apply at the system or ECM level , while Option C uses measurements taken <br /> at the whole - building , or whole-facility , level . Option A involves short-term ( if any) measurements , <br /> while <br /> Options B and C use short term and/or continuous or regular interval measurements during the term of the <br /> contract . Option D involves computer simulation techniques . <br /> Each option has advantages and disadvantages based on site -specific factors . <br /> The four options are described in the table below . <br /> Overview of M &V Options (from the FEMP/ IPMVP ) <br /> M &V option How savings are Typical Applications <br /> calculated <br /> A Partially Measured Retrofit Isolation Engineering calculations Lighting retrofit where <br /> using short-term or power draw is measured <br /> Savings are determined by partial field continuous post- retrofit periodically . Application <br /> measurement of the energy use of the measurements and of controls to vary the <br /> system ( s ) to which an ECM was applied ; stipulations . load on a constant speed <br /> separate from the energy use of the rest of the pump using a variable <br /> facility . Measurements may be either short- speed drive Power <br /> term or continuous . draw is measured on a <br /> spot basis , while varying <br /> Partial measurement means that some but not load . Operating hours of <br /> all parameter( s ) may be stipulated , if the total are specified/ stipulated . <br /> impact of possible stipulation error( s ) is not <br /> significant to the resultant savings . Careful <br /> review of the ECM design and installation will <br /> ensure that stipulated values fairly represent <br /> the probable actual value . <br /> Indian River County , Florida 17 Indian River County Phase 1 <br /> Phase I Rev . 06 /09 <br />