Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
Mr . Himanshu Mehta <br /> 11 July 2008 <br /> Page 9 <br /> documents . Resident engineering support services are expected to include engineers , <br /> administrative assistants, CADD operators , and word processors , as needed . Resident engineer <br /> support services are budgeted only for the construction period extending beyond that of the <br /> vertical expansion . <br /> As part of the Resident Engineering task, Geosyntec will prepare a final CQA closure <br /> certification report . The closure certification reports will include as-built record drawings for the <br /> Project . The report will contain a narrative describing, in detail , the aspects of field activities <br /> associated with the closure system construction, specifically with reference to the activities <br /> identified in this proposal . The report will also include a summary of all conformance and <br /> performance tests conducted, testing frequencies , and test results showing compliance with the <br /> Technical Specifications and the CQA plan . The documentation of construction activities <br /> (presented on daily summary reports, monitoring logs, test data sheets, nonconformance <br /> identification and corrective measures reports, and design change records) will be included as <br /> appendices to the final report . The as-built record drawings will be prepared for the Project, in <br /> CADD format, in order to illustrate the details of construction, any approved design changes , and <br /> other relevant information. <br /> The final CQA certification report and as -built record drawings will be signed and sealed by a <br /> registered professional engineer in the State of Florida. Geosyntec will prepare the report within <br /> 30 days of completing the construction activities . Five copies of the final CQA certification <br /> report will be submitted to FDEP for approval on behalf of SWDD . An electronic copy of as- <br /> built drawings in AutoCAD 2000 format will also be submitted to SWDD . <br /> BUDGET ESTIMATE <br /> A budget estimate for the scope of work outlined in Phase 1 and Phases 5 through 7 of this <br /> proposal is summarized in the following table, and a detailed budget estimate is provided as <br /> Attachment 2 . The budget estimate does not include permit fees that will be required at the time <br /> the permit application is submitted to FDEP . <br /> Phase 5 — Class I Closure Design and Permitting $ 189236 <br /> Phase 6 — Construction Procurement Services $ 139744 <br /> Phase 7 — Construction Support Services $ 90 , 725 <br /> TOTAL $ 1225705 <br /> Geosyntec will not exceed the cost estimate without prior approval and written authorization <br /> from SWDD . <br /> XR08168/JL80186 . doc <br /> � 111 �nyiyiecls I scientists I innovators <br />