Laserfiche WebLink
i ! <br /> Geos tec D 6770 South Washington Avenue, Suite 3 <br /> Titusville, Florida 32780 <br /> PH 321 . 269.5880 <br /> consultants FAX 321 .269.5813 <br /> www.geosymtec.com <br /> 7 May 2008 <br /> Himanshu Mehta, P . E . <br /> Managing Director <br /> Indian River County — Solid Waste Disposal District <br /> 1325 74th Avenue SW, <br /> Vero Beach, FL 32968 <br /> Subject : Proposal for AST Closures, Sampling, Relocation, Fueling System Design and <br /> Construction, Phase I ESA Due Diligence, and Completion of a NEPA Categorical <br /> Exclusion Package, Work Order # 15 <br /> Vero Beach, Florida <br /> Dear Mr. Mehta : <br /> Geosyntec Consultants (Geosyntec) is pleased to submit this fee proposal to Indian River County <br /> ( IRC ) Solid Waste Disposal District ( SWDD) for professional services associated with the <br /> closure and relocation of two aboveground storage tanks (ASTs) , the design and construction of a <br /> fueling area at the landfill , AST closure sampling and documentation, and the preparation of a <br /> Phase I ESA and National Environmental Policy Act (NEPA) Categorical Exclusion Package for <br /> an approximate 5 to 10 acre parcel west of the Gifford Convenience Center. This fee proposal <br /> has been prepared in accordance with the negotiated contract between Geosyntec and IRC <br /> SWDD . <br /> PROJECT UNDERSTANDING <br /> Geosyntec personnel and our subcontractors, PR&D , HCC Environmental Services , and FECC <br /> met with IRC staff in 2007 and again in March 2008 to develop a project scope of work <br /> associated with the petroleum-related work tasks . Based upon discussions with IRC staff the <br /> project scope consists of: (i) the preparation of design drawings for the proposed AST relocation <br /> area to be constructed at the landfill ; (ii) the construction of the fueling area (grading and <br /> concrete pad) and high- speed fuel dispensers (two) with card-reading system at the landfill ; (iii) <br /> the removal and relocation of the approximately 12 ,000-gallon double-walled AST located on <br /> IRC property along Gifford Road and placement on the constructed concrete pad at the landfill ; <br /> ( iv) removal of the concrete pad and bumper posts and re-grading the site where the 12 , 000- <br /> gallon AST was removed ; (v) closure of the existing approximately 8 , 000-gallon steel AST <br /> located at the landfill , including the performance of required soil borings , soil sampling, and the <br /> installation and sampling of a temporary monitoring well ; (vi) the preparation of an AST closure <br /> XR08051 R/CCR08045 R. DOC <br /> engineers I scientists I innovators <br />