My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2006-121
CBCC
>
Official Documents
>
2000's
>
2006
>
2006-121
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/10/2016 10:50:49 AM
Creation date
9/30/2015 9:38:52 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Agreement
Approved Date
04/11/2006
Control Number
2006-121
Agenda Item Number
7.H.
Entity Name
Department of Evironmental Protection
Subject
Grant Award for Main Relief Canal Pollution Control Structure No. G0182
Project Number
C9-99451505-0
Supplemental fields
SmeadsoftID
5589
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
d. Sample results below the Contract -specified PQL and above the highest calibration <br />standard shall be appropriately qualified. <br />8. Quality Control Blanks <br />a. If a Contracted analyte is detected in any analytical QC blank, the sample results that <br />are associated with the blank must be reported with the appropriate qualifier from <br />Chapter 62-160, F.A.C., unless the affected sample concentrations are at least 10 times <br />higher than the calculated QC blank concentration. <br />b. Sample results must be chronologically bracketed with acceptable beginning and ending <br />analytical QC blanks. <br />c. If a Contracted analyte is detected in the field blank, equipment blank or trip blank, the <br />result must be confirmed by reanalyzing a new aliquot of the blank unless the sample <br />concentration results associated with the blank are at least 10 times the calculated blank <br />concentration. The laboratory must investigate the blank contamination to determine <br />that positive blank results are not due to a laboratory error and report the affected <br />samples and field -generated blank results with appropriate qualifiers and/or comments. <br />9. If any quality control measure or calibration verification fails (including those specified <br />above), samples that are associated with the failure must be reanalyzed, if possible. <br />Sample data that are associated with a failed quality control measure or calibration must be <br />appropriately qualified as specified in Chapter 62-160, F.A.C. An explanatory comment <br />must be attached to the final report for each result that has a qualifier code other than U, I, <br />or A. Any additional qualifier codes used but not explicitly listed in Chapter 62-160, F.A.C. <br />must be identified and defined in the report. <br />10. The reported MDL and PQL for each sample must be adjusted for dilution factors and any <br />relevant preparation weights and volumes. <br />REMAINDER OF PAGE INTENTIONALLY LEFT BLANK <br />Revised 1/4/06 <br />DEP Agreement No. <br />G0162, <br />Attachment <br />H, <br />Page 9 <br />of <br />10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.