Laserfiche WebLink
than eight (8) full working hours) shall not be credited toward the specified durations. <br /> Training shall not be concurrent with on-going testing debugging or installation activities; <br /> but shall be a separate activity devoted exclusively to the instruction of the Owner's <br /> personnel in the operation and maintenance of the Manufacturer's equipment. Training <br /> shall be performed by qualified representatives of each equipment Manufacturer <br /> specifically skilled in providing instruction to operation personnel . Training shall provide <br /> an overview of operations and maintenance requirements and shall include but not be <br /> limited to: <br /> 1 . Description of unit and component parts , <br /> 2 . Operating capabilities and performance criteria, <br /> 3 . Operating procedures , <br /> 4 . Maintenance procedures , <br /> 5 . Servicing and lubrication schedules , <br /> 6 . Troubleshooting, and <br /> 7 . Electrical instrumentation and control requirements and interface as a minimum. <br /> The operating and maintenance data to be provided in accordance with <br /> Specification Section 01730 shall be used as a basis for training. <br /> F. A certificate from the Manufacturer stating that the installation of the equipment is <br /> satisfactory, that the unit has been satisfactorily tested, is ready for operation, and that the <br /> operating personnel have been suitably instructed in the operation, lubrication, and care of <br /> the unit shall be submitted before start-up and acceptance by the Owner. The certificate <br /> shall indicate date and time instruction was given and names of operating personnel in <br /> attendance. This certification shall be submitted on the certification sheet, the form of <br /> which is at the end of this section . <br /> G. See the detailed Specifications for additional requirements for furnishing the services of <br /> the Manufacturer's field service technician. <br /> H. For equipment furnished under Divisions other than 11 , 14, 15 , 16, and 17, the <br /> Contractor, unless otherwise specified, shall furnish the services of accredited field <br /> services technicians of the Manufacturer only when some evident malfunction or <br /> over-heating makes such services necessary in the opinion of the Engineer. <br /> 1 .28 OPERATING AND MAINTENANCE DATA <br /> A. Operating and maintenance data covering all equipment furnished shall be delivered <br /> directly to the Port St. Lucie office of Kimley-Horn and Associates, Inc., for approval <br /> within 60 days of shop drawing approval of each piece of equipment. No payment shall be <br /> made for equipment installed or stored on-site until the Engineer has approved the <br /> adequacy and completeness of the operating and maintenance data Data shall be prepared <br /> and submitted in full conformance with Section 01730 . Final approved copies of operating <br /> and maintenance data shall have been delivered to the Engineer on Owner's behalf two <br /> weeks prior to scheduling the instruction period with the Owner. <br /> END OF SECTION <br /> i <br /> i <br /> 044572017 <br /> 01170-8 <br />