2008-276 D
CBCC
>
Official Documents
>
2000's
>
2008
>
2008-276 D
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2026 1:12:14 PM
Creation date
10/1/2015 12:34:52 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
09/09/2008
Control Number
2008-276 D
Agenda Item Number
8.DD.
Entity Name
Interstate Engineering Corp.
Subject
South RO Water Treatment Plant Improvements Material and Equipment
Area
South RO Water Treatment Plant
Project Number
UCP 2859
Bid Number
2008027
Supplemental fields
SmeadsoftID
7558
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
B. The baseplate must be cast iron drip rim baseplate with integral drip channels incorporated <br />on each side. Each channel shall include an NPT connection and plug. The baseplate must <br />conform to ANSI/ASME B73.IM 1984 Standard Dimensions and have pre -drilled holes for <br />pump and motor mounting as well as grout holes. The baseplate design must provide <br />sufficient rigidity to maintain alignment between pump and motor. <br />2.09 COUPLING <br />A. The shaft coupling between the motor shaft and the pump shaft is to be a flexible spacer <br />coupling, Falk T10 1090T. The coupling must have a drop out center spacer to allow the <br />shafts to be disconnected without disturbing the pump or motor. Coupling hubs are to be <br />keyed into position on both shafts. The flexible rubber insert is to be EPDM. The coupling <br />must be selected properly by horsepower rating and shaft size for the pump and motor <br />combination specified. <br />B. An OSHA approved coupling guard shall be furnished over the coupling for protection. <br />2.10 MOTORS <br />A. Drive motor shall be horizontal squirrel -cage induction type as specified in Section 16490. <br />The motor shall be for use with a VFD. The motor nameplate horsepower rating must not be <br />exceeded at any head -capacity point on the pump curve. <br />B. Drive motor must be designed, manufactured, and tested in accordance with the latest revised <br />edition of NEMA MGI. The motor shall be the squirrel -cage inductior4 NEMA Design B, <br />single speed type. The motor nameplate horsepower rating must not be exceeded at any <br />head -capacity point on the pump curve. The motors must conform to the following: <br />Synchronous Speed <br />Horsepower <br />Voltage, Phase & Frequency <br />Mounting <br />Enclosure <br />Design <br />Service Factor <br />Duty Cycle <br />Ambient Temperature Rating <br />Winding Insulation <br />Temperature Rise <br />Starting Method <br />C. Provide motor modifications as follows: <br />1,800 rpm <br />150 HP (Maximum) <br />460V+10%, 3-phase, 60 Hz <br />Horizontal <br />TEFC <br />NEMA B <br />1.15 for continuous duty <br />Continuous <br />40 degrees C <br />Class F <br />Class B <br />Variable Frequency Drive <br />Manufacturers' standard <br />Sealed bearing <br />150,000 hours rating life is defined <br />by AFBMA standard <br />1. Space heaters to prevent moisture condensation, rating 120 volts, 200 watt <br />maximum, ac. <br />044572017 <br />11934-7 <br />