2 . PVC schedule 80 shall meet the requirements of ASTM standard D 17 85 for physical <br /> dimensions and tolerances . <br /> 3 . The marking on PVC Schedule 80 pipe shall meet the requirements of ASTM D1785 <br /> and state the material designation code , nominal pipe size , schedule of pipe, pressure <br /> rating in psi for water at 73 ° F . , the ASTM designation number D1785 and the NSF <br /> seal for potable water . <br /> 4 . Fittings used shall be PVC Schedule 80 and solvent welded in accordance with ASTM <br /> D1785 . <br /> 5 . Small Diameter PVC Pipe : PVC pipe smaller than 4 - inch shall be schedule 80 PVC <br /> plastic pipe with solvent weld fittings in accordance with ASTM D - 1785 . <br /> 6 _ PVC Drain Pipe: PVC drain pipe shall be PVC sewer pipe and fittings , ASTM D- <br /> 2729 . <br /> 7 . All underground sodium hypochlorite piping shall maintain constant slope as indicated <br /> on drawings . Provide top of pipe elevations every ten ( 10)-feet . Verify with <br /> Engineer. <br /> B . Containment Piping <br /> 1 . The pipe and fittings shall be of the same material for both the primary and secondary <br /> piping. The primary piping shall be Sch. 80 and that secondary pipe may be Sch. 40. <br /> 2 . Containment piping shall have centralizers and non-split, containment fitting <br /> termination test plugs with test port on secondary pipe. <br /> 3 . Containment piping to have rectangular FRP or PVC sumps with bolt down lid as <br /> indicated on the Contract Drawings . Sumps must be of sufficient depth to allow <br /> installation of secondary pipe drain valve and temporary connection of evacuation <br /> PUMP , <br /> 4 . Primary piping to be tested to 150 psig for 1 hour without any pressure drop (less than <br /> 2%). Any leaks, visual or test failure shall be convected at no cost to the Owner. After <br /> the primary piping pressure is successfully completed, the Secondary containment <br /> shall be pressure tested to 20 psi with less than 5% loss over 1 hour. During the <br /> secondary piping pressure test, the primary pipe shall remain full and pressurized to a <br /> minimum of 30 psi . <br /> 2.06 SULFURIC ACID AND ZINC ORTHO SYSTEM PIPING AND VALVES <br /> A. All piping and pipe fittings shall be Schedule 80 CPVC in the appropriate diameters, in <br /> accordance with the piping section of these specifications and the drawings . <br /> Tubing used to connect the pump ports to the suction and discharge headers shall be <br /> manufactured from PFA. Tube fittings shall be constructed from PFA and manufactured by <br /> Whitey, or equal . All fittings material must be compatible with 93% - 98% sulfuric acid by <br /> weight. <br /> 044572017 <br /> 15100-6 <br />