My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008-276 D
CBCC
>
Official Documents
>
2000's
>
2008
>
2008-276 D
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2016 10:29:43 AM
Creation date
10/1/2015 12:34:52 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
09/09/2008
Control Number
2008-276 D
Agenda Item Number
8.DD.
Entity Name
Interstate Engineering Corp.
Subject
South RO Water Treatment Plant Improvements Material and Equipment
Area
South RO Water Treatment Plant
Project Number
UCP 2859
Bid Number
2008027
Supplemental fields
SmeadsoftID
7558
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 . PVC schedule 80 shall meet the requirements of ASTM standard D 17 85 for physical <br /> dimensions and tolerances . <br /> 3 . The marking on PVC Schedule 80 pipe shall meet the requirements of ASTM D1785 <br /> and state the material designation code , nominal pipe size , schedule of pipe, pressure <br /> rating in psi for water at 73 ° F . , the ASTM designation number D1785 and the NSF <br /> seal for potable water . <br /> 4 . Fittings used shall be PVC Schedule 80 and solvent welded in accordance with ASTM <br /> D1785 . <br /> 5 . Small Diameter PVC Pipe : PVC pipe smaller than 4 - inch shall be schedule 80 PVC <br /> plastic pipe with solvent weld fittings in accordance with ASTM D - 1785 . <br /> 6 _ PVC Drain Pipe: PVC drain pipe shall be PVC sewer pipe and fittings , ASTM D- <br /> 2729 . <br /> 7 . All underground sodium hypochlorite piping shall maintain constant slope as indicated <br /> on drawings . Provide top of pipe elevations every ten ( 10)-feet . Verify with <br /> Engineer. <br /> B . Containment Piping <br /> 1 . The pipe and fittings shall be of the same material for both the primary and secondary <br /> piping. The primary piping shall be Sch. 80 and that secondary pipe may be Sch. 40. <br /> 2 . Containment piping shall have centralizers and non-split, containment fitting <br /> termination test plugs with test port on secondary pipe. <br /> 3 . Containment piping to have rectangular FRP or PVC sumps with bolt down lid as <br /> indicated on the Contract Drawings . Sumps must be of sufficient depth to allow <br /> installation of secondary pipe drain valve and temporary connection of evacuation <br /> PUMP , <br /> 4 . Primary piping to be tested to 150 psig for 1 hour without any pressure drop (less than <br /> 2%). Any leaks, visual or test failure shall be convected at no cost to the Owner. After <br /> the primary piping pressure is successfully completed, the Secondary containment <br /> shall be pressure tested to 20 psi with less than 5% loss over 1 hour. During the <br /> secondary piping pressure test, the primary pipe shall remain full and pressurized to a <br /> minimum of 30 psi . <br /> 2.06 SULFURIC ACID AND ZINC ORTHO SYSTEM PIPING AND VALVES <br /> A. All piping and pipe fittings shall be Schedule 80 CPVC in the appropriate diameters, in <br /> accordance with the piping section of these specifications and the drawings . <br /> Tubing used to connect the pump ports to the suction and discharge headers shall be <br /> manufactured from PFA. Tube fittings shall be constructed from PFA and manufactured by <br /> Whitey, or equal . All fittings material must be compatible with 93% - 98% sulfuric acid by <br /> weight. <br /> 044572017 <br /> 15100-6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.