My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008-276 D
CBCC
>
Official Documents
>
2000's
>
2008
>
2008-276 D
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2016 10:29:43 AM
Creation date
10/1/2015 12:34:52 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
09/09/2008
Control Number
2008-276 D
Agenda Item Number
8.DD.
Entity Name
Interstate Engineering Corp.
Subject
South RO Water Treatment Plant Improvements Material and Equipment
Area
South RO Water Treatment Plant
Project Number
UCP 2859
Bid Number
2008027
Supplemental fields
SmeadsoftID
7558
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
quarter tum clamps . <br /> 2.03 CIRCUIT BREAKERS <br /> A. Panelboards shall be equipped with circuit breakers with frame size and trip settings as shown <br /> on the Drawings . <br /> B . Circuit breakers shall be molded case , bolt-in type . <br /> C . Each circuit breaker used in 277 /480 Volt and 480 Volt panelboards shall have an interrupting <br /> capacity of not less than 45 ,000 Amps, RMS symmetrical . <br /> D . Circuit breakers shall be manufactured by the panelboard manufacturer . <br /> PART 3 EXECUTION <br /> 3 .01 INSTALLATION <br /> A. Mount boxes for surface mounted panelboards so there is at least 2-in air space between the <br /> box and the wall . <br /> B . Install markers on the front cover of all panelboards which identify the voltage rating. Markers <br /> shall be made of self sticking B -500 vinyl cloth printed with black characters on an Alert <br /> Orange background, 2- 1 /4-in high by 9-in wide, Style A as manufactured by W.H. Brady Co. <br /> or equal . <br /> C . Install a 1 -in by 3 -in nominal laminated plastic nameplate with 1 /2-in white letters on a black <br /> background on each panelboard. Nameplates shall be stainless steel screw mounted. <br /> D. Top of cabinets shall be mounted 6 feet-0-inch above the floor, properly aligned and adequately <br /> supported independently of the connecting raceways. <br /> E . All wiring in panelboards shall be neatly formed, grouped, and identified to provide a neat and <br /> orderly appearance . A typewritten directory card identifying all circuits shall be placed in the <br /> card holder inside the front cover. <br /> F . All panelboards shall be protected from physical damage, water damage, moisture, corrosion, <br /> dirt and dust during construction. Any panelboard judged to be unacceptable by the Owner' s <br /> j Representative shall be replaced by the Contractor at no additional cost to the Owner. <br /> 3 .02 CLEANING <br /> I <br /> A. Remove all rubbish and debris from inside and around the equipment. Remove dirt, dust or <br /> concrete spatter from the interior and exterior of the equipment using brushes, vacuum cleaner <br /> ( or clean lint-free rags. Do not use compressed air. <br /> END OF SECTION <br /> i <br /> - 044572017 <br /> I 16470-3 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.