My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008-276 D
CBCC
>
Official Documents
>
2000's
>
2008
>
2008-276 D
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2016 10:29:43 AM
Creation date
10/1/2015 12:34:52 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
09/09/2008
Control Number
2008-276 D
Agenda Item Number
8.DD.
Entity Name
Interstate Engineering Corp.
Subject
South RO Water Treatment Plant Improvements Material and Equipment
Area
South RO Water Treatment Plant
Project Number
UCP 2859
Bid Number
2008027
Supplemental fields
SmeadsoftID
7558
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> b . Provision to padlock unit disconnect handles in the OFF position with up to three <br /> padlocks . <br /> c . Mechanical interlock with bypass to prevent opening unit door with disconnect in the <br /> ON position , or moving disconnect to the ON position while the unit door is open . <br /> d . Mechanical split-type terminal blocks for disconnecting external control wiring. <br /> e . Auxiliary contact on unit disconnect to isolate control power when fed from an <br /> external source . <br /> f. Disconnect operating handles and control devices mounted on the removable units . <br /> g . All compartments shall have laminated wiring diagrams fastened to the inside of each <br /> compartment door. Compartments containing motor starters shall have laminated <br /> wiring diagrams and heater tables fastened to the inside of the compartment door. <br /> Compartments containing panelboards shall have circuit directories consisting of two <br /> ply laminated plastic, with black face and white core fastened to the inside of the <br /> compartment door . <br /> D . Bus Systems <br /> 1 . Main horizontal bus: Tin plated copper, bolted joints, accessible from the front of the <br /> structure, fully rated throughout the lineup. <br /> 2 . Vertical section bus : Tin plated copper, full height, totally insulated and isolated by glass <br /> polyester barriers with shutters to cover stab openings when units are withdrawn. Provide <br /> fishtape barriers to isolate bottom wireways from lower ends of vertical bus. <br /> 3 . Vertical buses used for a tie circuit breaker or tie feeder lugs shall be rated for a <br /> continuous capacity equivalent to the main horizontal bus rating. <br /> I <br /> 4 . Horizontal ground bus : Provide a 1 /4-inch by 2 -inch (minimum) tin plated copper <br /> uninsulated ground bus in each section equipped with lugs for termination of feeder and <br /> j branch circuit ground conductors . Connect to ground bus in adjacent sections with splice <br /> plates. <br /> 5 . The buses shall be sized for a maximum current density of 1200 Amps per square inch. <br /> I <br /> E. Wiring <br /> I1 . Wiring: Stranded copper, minimum size No. 14 AWG, with 600 Volt, 90 degree C, flame <br /> retardant, Type MTW thermoplastic insulation, NEMA Class U-S , Type B . Line side <br /> 1 power wiring shall be sized for the full rating or frame size of the connected device. <br /> 2 . Identification: All wiring shall be numbered with type written heat shrinkable type wire <br /> markers at each termination point, color coding per NEMA Standards and the NEC. <br /> lForeign voltage control wiring shall be yellow. <br /> l <br /> 044572017 <br /> 16480-3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.