2008-276 D
CBCC
>
Official Documents
>
2000's
>
2008
>
2008-276 D
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2016 10:29:43 AM
Creation date
10/1/2015 12:34:52 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
09/09/2008
Control Number
2008-276 D
Agenda Item Number
8.DD.
Entity Name
Interstate Engineering Corp.
Subject
South RO Water Treatment Plant Improvements Material and Equipment
Area
South RO Water Treatment Plant
Project Number
UCP 2859
Bid Number
2008027
Supplemental fields
SmeadsoftID
7558
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 .02 CONSTRUCTION <br /> A. Enclosure <br /> 1 . Enclosure type shall be NEMA Type 1 A unless otherwise approved by Owner ' s <br /> Representative . <br /> B . Structure <br /> 1 . Motor control centers shall consist of a series of metal enclosed , free -standing , dead front <br /> vertical sections bolted together to form double wall construction between sections . <br /> Individual vertical sections shall be nominally 90-in high, 20-in wide and 20 -in deep <br /> unless otherwise required . Bottom channel sills shall be mounted front and rear of the <br /> vertical sections extending the full width of each shipping split. Top of each section shall <br /> have removable plates with lifting angle. Make provisions for field installation of <br /> additional sections to each end and provide full depth cover plates (rodent barriers) at each <br /> end of the motor control center channel sills. <br /> 2 . Provide continuous top and bottom horizontal wireways extending the full width of the <br /> line-up , isolated from the horizontal bus. Provide a 4-in wide, full height, vertical wireway <br /> in each section, equipped with a hinged door and cable supports. Vertical wireway shall be <br /> isolated from the bus and device compartments. Wireways openings shall have rolled <br /> edges or protective grommets . <br /> 3 . Provide individual, flange formed, pan type door with concealed hinges and quarter turn <br /> latches for each device compartment and future space. Doors shall be removable. Door <br /> removal shall not be required to withdraw starter units or feeder tap devices . <br /> 4. Motor control centers shall be designed for against-the-wall or back-to-back mounting. All <br /> wiring, bus joints and other mechanical parts requiring tightening or other maintenance <br /> shall be accessible from the front or top . <br /> C . Unit Compartments <br /> 1 . Provide individual compartments for each removable combination starter and feeder tap <br /> device unit. Each vertical section shall accommodate a maximum of six compartments. <br /> Steel barriers shall isolate the top, bottom and sides of each compartment from adjacent <br /> units and wireways. Removable units shall connect to the vertical bus in each section with <br /> tin plated, self aligning, pressure type copper plug connectors. Size 5 and larger starter <br /> units may be wired directly to the bus. Removable units shall be aligned in the structure on <br /> guide rails or shelves and secured with a cam latch mechanism or racking screw. <br /> 2 . Provide individual, isolated compartments for all fixed mounted devices including circuit <br /> breakers, cable lugs, metering, relaying and control devices. Main and bus tie circuit <br /> breakers shall be wired directly to the main horizontal bus. All bus connections shall be <br /> fully rated. <br /> 3 . Provide the following features: <br /> I <br /> a. Provision to padlock removable units in a partially withdrawn TEST position, with <br /> the bus stabs disengaged. <br /> 044572017 <br /> 16480-2 <br />