My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008-276 D
CBCC
>
Official Documents
>
2000's
>
2008
>
2008-276 D
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2016 10:29:43 AM
Creation date
10/1/2015 12:34:52 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
09/09/2008
Control Number
2008-276 D
Agenda Item Number
8.DD.
Entity Name
Interstate Engineering Corp.
Subject
South RO Water Treatment Plant Improvements Material and Equipment
Area
South RO Water Treatment Plant
Project Number
UCP 2859
Bid Number
2008027
Supplemental fields
SmeadsoftID
7558
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
10 . The VFD shall be relatively insensitive to waveform distortion, especially the waveform <br /> distortion caused by the VFD . <br /> 11 . A six pulse converter section consisting of a three-phase , full wave phase controlled <br /> rectifier or diode bridge converter to convert incoming A . C . power to constant voltage <br /> D . C . <br /> 12 . D . C . bus capacitors and inductors necessary to filter rectification ripple . <br /> 13 . Three-phase full wave inverter to construct an A . C . wave form, with minimum harmonic <br /> content, at any frequency between 0 and 60 Hz. to control motor speed . Motor terminal <br /> voltage shall be controlled in proportion to output frequency such that the voltage to <br /> frequency ratio remains essentially constant . <br /> 14 . Adjustable volts/Hz ratio . <br /> 15 . Adjustable PWM carrier frequency. <br /> 16 . Independent acceleration and deceleration controls , adjustable from 0 to 600 seconds. <br /> 17 . The drive shall accommodate the opening of a disconnect between the drive output and <br /> the motor, while under full load. <br /> 18 . All input/output signals shall be wired to terminal strips for field terminations . Provide <br /> an RS232 or RS485 port for remote computer monitoring. <br /> 19 . Provide panel mounted master reset pushbutton for all safety and overload circuitry. <br /> 20 . Elapsed motor run-time meter with six digit nonreset indicator operable through auxiliary <br /> contacts from the VFD. <br /> 21 . Provide typewritten terminal block schedules and wiring diagrams within a plastic holder <br /> permanently attached to the inside door of the VFD . <br /> 22 . Adjustable current limit to control the maximum controller output current during starting <br /> and running. <br /> 23 . Minimum and maximum speed adjustment. Minimum speed shall be factory set at 50 <br /> percent of motor nameplate rated full load speed. Maximum speed shall be preset to 100 <br /> percent of motor nameplate rated speed or as required by existing motor nameplate full <br /> load current. The drive shall provide at least three adjustable setpoints to lock out <br /> continuous operation at frequencies which may produce mechanical resonance. <br /> 24. The VFD shall be capable of starting into a motor rotating at any speed without tripping. <br /> 25 . Key circuit points shall be monitored by light emitting diodes, (LEDs) to assist in <br /> troubleshooting. Each shall be labeled and referenced to the instruction manual. <br /> 26. The VFD shall be operable with the output open circuited. <br /> i <br /> 044572017 <br /> 16483 -6 <br /> i <br />