My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008-276 D
CBCC
>
Official Documents
>
2000's
>
2008
>
2008-276 D
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2016 10:29:43 AM
Creation date
10/1/2015 12:34:52 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
09/09/2008
Control Number
2008-276 D
Agenda Item Number
8.DD.
Entity Name
Interstate Engineering Corp.
Subject
South RO Water Treatment Plant Improvements Material and Equipment
Area
South RO Water Treatment Plant
Project Number
UCP 2859
Bid Number
2008027
Supplemental fields
SmeadsoftID
7558
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
directly on AC power (across the line) at full motor speed and load. Motor noise when <br /> operating on VFD shall not exceed full speed measured noise levels when operating at <br /> reduced motor load and speed conditions between 40 and 100 percent of output <br /> frequency . Noise shall be measured in accordance with IEEE Standard 85 . Output noise <br /> filters shall be provided where necessary to meet this requirement . <br /> 7 . Speed regulation ±3 percent without the use of a motor mounted tachometer . <br /> F . Features <br /> 1 . Provisions for the following control signals for automatic and remote manual operations : <br /> a . Start/stop signal from a single remote dry contact closure (maintained contact) . <br /> b . A linear 4-20 mA, 24 VDC input signal for remote speed (output frequency) control <br /> proportional to 20 - 100 percent output speed (frequency) . This range (20 - 100 <br /> percent) shall be field adjusted for proper control coordination . Input signal isolation <br /> shall be provided . <br /> c . Remote setpoint adjustment from a single 0- 10 VDC input signal . Once the setpoint <br /> has been provided to the VFD, the VFD shall operate to maintain this setpoint <br /> through feedback loop control from a linear 4-20 mA, 24 VDC input signal . This <br /> operation shall continue until a new remote setpoint is received even if the remote <br /> setpoint signal is lost. <br /> 2 . Controller keypad to program drive parameters as specified herein. <br /> 3 . Hand/off/automatic selector switch with auxiliary contacts as required by the Drawings. <br /> I <br /> 4 . Potentiometer or equivalent for manual speed (output frequency) control . <br /> 5 . Drive controller output digital type indicator and transmitter calibrated in percent of <br /> maximum output frequency. Transmitter shall provide a linear, isolated, 4-20 mA, 24 <br /> VDC output proportional to 0 - 100 percent (initial setting) of maximum output <br /> ifrequency. <br /> 6 . Incoming line molded-case switch or disconnect, mechanically interlocked with the <br /> variable frequency drive cabinet door handle, shall be provided. These shall be 250A, <br /> minimum with a minimum withstand rating of 25 ,000 amperes or as indicated on the <br /> drawings . These switches shall be padlockable in the "OFF" position. Incoming line <br /> i circuit breakers or fuses as required by the VFD manufacturer shall be provided. These <br /> shall be current-limiting if specified by the manufacturer. <br /> 7 . 120V a.c . control circuitry. <br /> 8 . Provision for automatic emergency shutdown without rampdown, in any mode, actuated <br /> by large, red, illuminated, local emergency pushbutton. <br /> I <br /> ' 9 . One set of DPST auxiliary contacts for each remote indication of status as required by the <br /> Drawings . <br /> 1 <br /> 044572017 <br /> 16483 -5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.