Official Document Type
Contract
Approved Date
09/09/2008
Control Number
2008-276 D
Agenda Item Number
8.DD.
Entity Name
Interstate Engineering Corp.
Subject
South RO Water Treatment Plant Improvements Material and Equipment
Area
South RO Water Treatment Plant
Project Number
UCP 2859
Bid Number
2008027
Supplemental fields
SmeadsoftID
7558
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C . Operation <br /> 1 . Accomplish speed control by adjusting both the output voltage and frequency to the <br /> motor. Convert input AC power to a constant voltage DC which is then converted to <br /> adjustable voltage and frequency three-phase AC utilizing pulse width modulation <br /> technology to operate the connected motor at the desired speed . The VFD shall not <br /> induce excess power losses in the motor. The VFD shall not produce voltage impulses <br /> deemed harmful to the motor insulation by the motor Manufacturer . <br /> 2 . Each VFD shall be specifically designed for use with variable torque pumping loads . <br /> Soft-start control circuitry shall limit in -rush current, not to exceed 100 percent of motor <br /> full load current, under all manual and automatic operating conditions . When power <br /> outages occurs , the drive system shall shut down in an orderly manner. Upon restoration <br /> of A.C . power, the motors shall restart sequentially and run at a rate depending upon the <br /> reference requirements , by the sequencing logic controller. <br /> D . Ratings <br /> 1 , Line Voltage : 460 volts, three-phase , (+/-) 10 percent continuous . <br /> 2 . Line Frequency: 48 -62 Hz. <br /> 3 , Ambient Temperature: 0 degrees C to 40 degrees C . <br /> 4 , Altitude : Up to 3300 feet above sea level . <br /> 5 . Maximum Transient Current Variable Torque: 1 .00 continuous, 1 . 10 one minute; <br /> Constant Torque : 1 .00 continuous, 1 . 50 one minute <br /> 6 . Power Factor: Minimum 0 . 95 throughout speed and load range . Power factor correction <br /> by capacitors shall not be acceptable . <br /> E. Performance <br /> 1 . Efficiency. Above 97 percent at 100 percent output frequency (full speed) and full load <br /> as well as above 95 percent at all reduced load and speed conditions between 40 and 100 <br /> percent output frequency. <br /> 2 . VFD Inrush Current: Limited to less than 100 percent of motor full load current. <br /> 3 . Duty Cycle: 6 starts per hour. <br /> 4. Output Frequency Range; 6 hertz to 60 hertz, cogless, with adjustable minimum and <br /> maximum to match the required operating conditions . <br /> 5 . Output fiequency stability (+/-) 1 .0 <br /> percent, continuous <br /> 6. Pulse Width Modulation (PWM) controller carrier frequency regulation shall be designed <br /> for " quiet" motor operation. Induced motor noise when operating at full speed and load <br /> on VFD shall not exceed 5 dBA above the measured motor noise level when operating <br /> 044572017 <br /> 16483 -4 <br />