Laserfiche WebLink
Indian River County Administration Complex <br /> Bldg. I — 2 nd Floor East End Punchlist — Friday 04/06/07 <br /> April 16, 2007 <br /> Page 15 <br /> Production 403 <br /> 1 . Outside of Door 403A finish needs to be cleaned of adhesive. <br /> 2. Right side hinge side of 403A scratch in the wood door. Also, hollow metal door frame needs to be touched <br /> up with paint and cleaned of carpet adhesive . <br /> 3 . Vinyl base installed in this room. <br /> 4. Right of door 403A vinyl base does not set flush to the wall at the door frame and also at the cabinetry to the <br /> right. There is only small portion of vinyl base on one section installed and the remainder of the room does <br /> not have vinyl base installed . <br /> 5. Two ceiling tiles missing in this room. <br /> 6. Cabinet wall, upper cabinets to the top right of the upper cabinets ceiling grid and tile has paint on it. <br /> 7. VCT needs to be cleaned where it abuts the carpet of carpet adhesive. <br /> 8. Backsplash needs to be cleaned of paint on the North wall left side. <br /> Office 404 <br /> 1 . Door frame 404 needs to be repainted on the outside and inside. Also to the left bottom right on the inside of <br /> the Office 404 there is a scratch on the door. <br /> 2. To the right of Door 404, adhesive on the drywall needs to be cleaned and repainted. Also, paint from the <br /> metal window lite frame needs to be removed from the door. <br /> 3. Drywall on light switch to left of Door 404 needs to be sanded and repainted. Opening cut too large and <br /> fingerprints need to be cleaned . <br /> 4. Inside corners of vinyl base are not adhering properly. No vinyl base is installed in this area. <br /> 5 . West wall duplex outlet drywall needs to be sanded and repainted where it abuts the outlet. <br /> 6. South inside comer to the left of quad outlet needs to be repainted. <br /> 7. Vinyl base in this room does not set flush to the carpet in numerous areas. Unacceptable . <br /> 8. Five ceiling tiles not in place at this time. <br /> 9. Ceiling grid to the right of the exterior window, 2 tiles off of that exterior wall appears to have fire caulking <br /> on it needs to be cleaned. <br /> 10. West wall, middle of the wall, I " grid off the wall is damaged and bent. <br /> Open Office Area 405 <br /> 1 . Vinyl base installed in this area. <br /> 2 . Inside comers of the vinyl base have been cut, they do not fit tight. Needs to be looked at. <br /> 3. Exterior wall, South wall, drywall above Data Outlet 5D & 6D is not even, needs to be sanded and repainted <br /> to set to have a flush condition, very visible. <br /> 4. Data Outlets 7D, 8D, 9D & 10D need to be cleaned of paint. <br /> 5 . Quad outlet to the left of Data Outlet 9D & l OD on the South wall needs to be cleaned of paint, drywall needs <br /> to sanded and repainted on the bottom edge, irregular. <br /> 6. East wall, carpet adhesive needs to be removed from the wall and any scratches and dents in the drywall <br /> above the vinyl base needs to be patched and repaired. <br /> 7 . Door 405A — Door frame needs to be cleaned of carpet adhesive and repainted where the paint finish has been <br /> scratch. <br /> 8. Right side of Door 405A the drywall has been caulked, needs to be repainted. Also to left of 405A needs to <br /> be sanded and repainted . A semi —gloss has been put onto the drywall. This needs to be sanded, caulked and <br /> repainted. <br /> 9. North wall adjacent to Storage Room 406 needs to be touched up with paint where it has been scratched in <br /> numerous locations above the vinyl base on the East end and about the middle of the wall. <br /> D O N A D I O <br /> & Associates, Architects, P.A . <br />