2007-263E
CBCC
>
Official Documents
>
2000's
>
2007
>
2007-263E
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/14/2016 10:56:50 AM
Creation date
9/30/2015 11:03:14 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Migration
Approved Date
08/20/2007
Control Number
2007-263E
Agenda Item Number
County Administrator signature
Entity Name
Donadio & Associates
Subject
Punch List Bldg. 2 1st Floor West and Center Portion
Area
New County Administration Buiding #2
Supplemental fields
SmeadsoftID
6493
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Indian River County Administration Complex <br /> Bldg. 2 - 1st Floor Punch List - Friday - 06/29/07 <br /> July 09, 2007 <br /> Page 11 <br /> Office 219 (continued) <br /> 21 . Right outside comer of Office 219 the northeast comerjust to the left and above the vinyl base approximately <br /> 5ft. dents in the drywall need to be patched and repaired. <br /> 22. Work area cabinetry south of Office Area 218 and 219?? ? ????? <br /> 23. East end at the filler strips, filler strips edges are chipped and damaged where it has been caulked to the <br /> drywall. <br /> 24. Vinyl base to the bottom left of this eastern end is not adhered to the drywall. <br /> 25 . Above the back splash at the outside corner of this eastern wall between the upper cabinets and the base <br /> cabinets fingerprints on the paint finish. <br /> 26. Above the wall cabinets at the east end, left inside corner and approximately off of that needs to be patched, <br /> repainted and repainted. <br /> 27. Cabinetry needs to be cleaned of drywall dust, dirt and debris . <br /> 28. West end below the wall cabinets where there is no base cabinets installed the inside corner about the middle, <br /> drywall is damaged needs to be patched and repaired. Also, coming off this same area the outside corner of <br /> the wing wall needs to be patched, repaired and repainted. <br /> 29 . Ceiling tile to the left of th4eoutside corner of Office Area 219, tile is chipped. <br /> 30. Ceiling gird on the west end of the upper cabinets up above the cabinets do not set flush and level to the wall. <br /> 31 . Ceiling tile in Open Office Area 218 approximately 6 tiles not in place. <br /> 32. Ceiling tile at the exit device between boxed out column and Door 215 at the exit sign, tile is damaged. That <br /> is also true in this same area, 2 or 3 tiles near the return air grille and the 2x2 light fixture in front of Door 215 <br /> and 216. <br /> 33 . Ceiling tile the 5`h ceiling tile off the north Training Room wall and the 4th tile off the boxed out column to the <br /> left of Door 215 tile is chipped. <br /> Storage Room 220 <br /> 1 . Transition strip needed between VCT and ceramic tile. <br /> 2 . Hollow metal door frame 220 needs to be caulked where it abuts the masonry on the inside both the jambs <br /> and the heads . <br /> 3 . Door 220 needs to be cleaned of dirt, drywall dust, etc. <br /> 4. Hollow metal door frame needs to be completely repainted. <br /> 5 . No vinyl base installed. <br /> 6. Floor needs to be cleaned of dirt and debris . <br /> 7. All penetrations in the masonry wall needs to be sealed properly and closed off. <br /> S. Light fixture lenses are loose, some are damaged this needs to be replaced. <br /> 9. Grout joints in numerous areas are cracked, these need to be filled in especially on the north block wall and <br /> the south block wall. <br /> 10. This room needs an additional coat of paint. <br /> 11 . Electrical outlets on the east wall opening cut out very large and irregular, this needs to be patched and <br /> repaired properly. That is also true of the light switch to the left of Door 220. <br /> 12. Drywall around fire alarm horn strobe to the right of Door 220 opening cut too large, needs to be patched and <br /> repaired. <br /> Receiving Room 221 <br /> 1 . Drywall to the left and right of Door 221 needs to be touched-up with paint. <br /> 2 . Transition strip needed between ceramic tile and sealed concrete. <br /> 3 . Hollow metal door frame bottom left metal wire needs to be removed and door needs to be caulked. <br /> 4 . Exterior Door 221 B needs to be repainted on the inside and also hollow metal frame needs to be caulked <br /> where it abuts the masonry on the inside. <br /> D O N A D I O <br /> & Associates , Architects, P.A. <br />
The URL can be used to link to this page
Your browser does not support the video tag.