My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2007-263
CBCC
>
Official Documents
>
2000's
>
2007
>
2007-263
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/13/2016 12:53:18 PM
Creation date
9/30/2015 11:02:22 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Agreement
Approved Date
08/20/2007
Control Number
2007-263
Agenda Item Number
County Administrator Signature
Entity Name
Turner Construction
Subject
Certificate of Substantial Completion
Area
New County Administration Bldg.
Supplemental fields
SmeadsoftID
6488
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Indian River County Administration Complex <br /> Bldg. 1 - 1st Floor - West - Punch List - Tuesday - July 24, 2007 <br /> August 02, 2007 <br /> Page 25 <br /> Men 's Restroom 112 (continued) <br /> 18. Light fixture between the water closet and the Handi-cap urinal recessed can not working. <br /> 19. Back splash needs to be caulked at the vanity where it abuts the drywall finish . <br /> 20. Drywall finish to the right of the soap dispenser and to the right of the front face of the sink counter in this <br /> general area black fingerprints and paint completely all over the drywall finish. <br /> 21 . Ceramic tile needs to be replaced at the drain line where it has been cut to receive the drain line. Opening cut <br /> too large unacceptable. Also, in this same area escutcheon plate needs to be pulled to the ceramic the once it <br /> is fixed. <br /> 22. Right inside corner needs to be grouted neat and clean undemeath the counter top. <br /> 23 . Bottom right inside corner at ceramic file base grout needs to be cleaned, it is excessive. <br /> 24. Ceiling grid where it abuts the drywall ceiling, unacceptable grid is not level and plumb to the drywall, very <br /> rough and irregular and outside edge needs to be completely redone and repainted the complete length. <br /> Women 's Restroom 113 <br /> 1 . Door 113 outside face needs to be cleaned of dirt and debris . <br /> 2. 2x2 light fixture in front of door 113 that is emergency fixture not working. <br /> 3 . Ceramic tile floor in front of lavatory and on the counter top full of drywall mud, spatters. <br /> 4. Right side of hollow metal frame need to be sanded, caulked and repainted. <br /> 5 . Hollow metal frame needs to be touched-up with paint where it has been chipped . <br /> 6. Fire alarm horn strobe needs to be cleaned of drywall mud. <br /> 7. Floor drain needs to be properly grouted flush to the ceramic tile floor. <br /> S. West wall, right hand side corner top edge needs to be cut in neat and clean , remove paint and grout. <br /> 9. Right inside corner to the right of the water closet voids in the grout and also excessive grout at the top edge <br /> of the ceramic tile. <br /> 10. Ceramic tile grout at the flush valve of escutcheon plate above the flush valve and in the general area needs to <br /> be patched and repaired. <br /> 11 . Grout joint to the left of the lavatory and the Handicap stall needs to be repaired, voids in the grout. That is <br /> also true at the grout joint at the bottom connection angle at the toilet partition. <br /> 12. Ceramic tile grout joint at the center toilet stall left of the flush valve voids in the grout needs to be repaired. <br /> Also, above the flush valve grout needs to be repaired. <br /> 13 . Ceramic tile to the left, that is the water closet adjacent to the lavatory sinks ceramic tile is out of plumb needs <br /> to be corrected. Voids in the grout joints also. <br /> 14. Back splash needs to be caulked properly where it abuts the ceramic tile. Also, dirt and debris needs to be <br /> removed, needs to be a cleaned caulked joint. <br /> 15 . Far left inside comer between the ceramic tile wainscot, the back splash, and the drywall finish voids need to <br /> be filled. <br /> 16. Ceramic tile opening cut too large at escutcheon plate for drain line, this needs to be corrected. <br /> 17 . Under counter left inside corner finish needs to be repaired. <br /> 18 . Ceiling grid to the top left of the lavatory just in front of the dropped header has drywall finish on it, needs to <br /> be cleaned. <br /> 19 . Ceiling grid along the drywall ceiling at the recessed can light unacceptable, voids between the grid and the <br /> ceiling, outside edge finish is chipped, this needs to be repainted. <br /> 20. Drywall at the exhaust fan grille needs to repainted. <br /> 21 . Complete drywall soffit needs to be repainted , unacceptable paint finish. <br /> D O N A D I O <br /> & Associates, Architects, P.A. <br />