Indian River County Administration Complex <br /> Bldg. 1 - 1st Floor - West - Punch List - Tuesday - July 24, 2007 <br /> August 02, 2007 <br /> Page 26 <br /> Corridor 114 <br /> 1 . Door 114A metal frame of view light on the bottom left and bottom side left needs to be repainted. <br /> 2. Tile needs to be cleaned of dirt and debris. <br /> 3 . Two ceiling tiles missing above Door 114A. <br /> 4. Ceiling tile at the sprinkler head above Door 114A two tiles in this area are damaged. <br /> 5. Numerous ceiling tiles are not in place in this area. <br /> 6. Perimeter of ceiling grid along the walls the complete perimeter of Corridor 114 needs to be cleaned of paint. <br /> 7 . Ceiling gird along the boxed out column opposite Door 116 covered with paint, needs to be cleaned. <br /> 8 . Ceiling tile in front of door 116 stain on the tile and also to the left of that tile is chipped at the sprinkler head <br /> location. <br /> 9 . Ceramic file base needs to be cleaned of paint at the top edge. <br /> 10. Left side of Door 504 needs to be sanded, caulked and repainted. That is also true of the head of Door 504 <br /> where it abuts the drywall. <br /> 11 . Left side of Door 110 needs to be sanded and repainted. That is also true of the head at 110 needs to be <br /> sanded, caulked and repainted. <br /> 12. Ceiling tiles missing above Door 504 and 110. <br /> 13 . Ceiling grid around the return air grille in front of Door 504 has dirt on it. <br /> 14. To the right of Door 117 hollow metal frame drywall is not plumb, bottom right frame flush to the drywall , <br /> top edge is out approximately 1/4 of an inch. Also, right side of this boxed out column area to the right of <br /> Door 117 needs to be sanded and repainted above the tile. <br /> 15 . Right inside corner to the right of Door 506 needs to be sanded, caulked and repainted . <br /> 16. Outside edge of hollow metal frame 506 needs to be sanded and repainted. <br /> 17. Top head of hollow metal frame where it abuts the drywall needs to be sanded, caulked and repainted. <br /> 18. Right side of hollow metal frame 116 needs to be sanded, caulked and repainted at the drywall. That is also <br /> true at the left side and the head. <br /> 19. Wood trim around elevator needs to be caulked in place . <br /> 20. Push button for elevator is not plumb and level to the floor. <br /> 21 . Ceiling grid coming off the left of Door 114 approximately the 3rd grid, damaged. <br /> 22 . Ceiling tile directly in front of exit sign coming off of Door 114, damaged. <br /> 23 . Ceiling grid to the left of the sprinkler head that is just in front of the exit sign in front of Door 114, fire <br /> caulking on the grid needs to be cleaned. <br /> 24. Ceiling tile damaged that is the tile coming off the left side of the fire extinguisher cabinet to the left of Door <br /> 116, center of the hallway. <br /> 25 . Ceiling tile coming off the left top corner of Door 506 the I " ceiling file off the wall is damaged. <br /> 26. Ceiling tile coming off the boxed out column to the left of Door 117 the 3rd and 6`h ceiling tiles are damaged <br /> and also grid in this area finish has been chipped. <br /> 27 . Ceiling grid to the right of Door 117 at the sprinkler head finish is damaged. <br /> Office 116 <br /> 1 . Inside face bottom right of glass paint needs to be removed. Also, left side where the glass abuts the metal <br /> frame needs to be cleaned of paint. <br /> 2. Bottom sill of metal frame for view light finish is peeling, needs to be repainted. Also, top left paint <br /> overspray, not acceptable . Paint runs in the frame. <br /> 3 . Furniture installed in this area. <br /> 4. South wall west end to the right between the fire alarm horn strobe and the right inside comer, drywall finish <br /> is damaged, needs to be patched and repaired. <br /> D O N A D I O <br /> & Associates, Architects, P.A. <br />