Laserfiche WebLink
-IRC Adm nistration Complex <br /> Property Appraisers Office - Punch List - Friday - 07/06/07 <br /> July 10, 2007 <br /> Page 7 <br /> Conference Area 612 & 613 (continued) <br /> 23 . Borrowed light 613 BLl the complete length of sill of the hollow metal frame in right and left side jambs <br /> need to be repainted. <br /> 24. Drywall to the right of borrowed light 613 BLl needs to be sanded and repainted, drywall is irregular around <br /> the wall mounted door stop. <br /> 25. Hollow metal frame 613B left side of the frame needs to be repainted. Also, drywall at the hinge location <br /> needs to be sanded and repainted. That is also true the bottom hinge and middle hinge, drywall very rough and <br /> irregular. <br /> 26. Right side of hollow metal frame needs to be sanded and repainted. <br /> 27 . Top right corner of hollow metal frame 613B rough and irregular needs to be sanded and repainted. <br /> 28. Drywall at the head of hollow metal frame 613B needs to be sanded, caulked and repainted. <br /> 29. Johnson control box to the right of Door 613B needs to be cleaned of drywall mud and paint. <br /> 30. Screws missing in cover plate for light switch to the right of door 613B and also light switch devices need to <br /> be cleaned of paint. <br /> 31 . Exterior wall on the east end between the l ' and 2 d windows , drywall irregularity approximately about 30 <br /> inches off the floor and dirt on the drywall. <br /> 32. Window sill at the 2°d window coming form the east end of the room on the exterior wall needs to be caulked. <br /> 33. Window sills the 3rd and 4" window coming from the east exterior wall need to be re-caulked at the drywall <br /> jamb. <br /> 34. Ceiling tile to the right of Door 612 is chipped along the wall at the tar from on the wall. ? ?? <br /> 35. Ceiling grid at the return air grille in front of Door 612 finish is damaged. Also the ceiling tile is chipped at <br /> the sprinkler head adjacent to this same return air grille. <br /> 36. Ceiling the to the right of Door 612 between the light fixture and the supply air grille, ceiling tile is chipped <br /> and damaged. <br /> 37. Ceiling tile for the top left of Door 613A edges area chipped. <br /> 38. Ceiling tile coming directly off of Door 613A the 1" the off the exterior wall , tile is chipped. <br /> Open Office Area 614 <br /> 1 . Office furniture is installed in this office at this time . <br /> 2. Outside drywall at the head of Door 613B needs to be sanded, caulked and repainted. <br /> 3 . Bottom right drywall to the right of hollow metal door fame needs to be sanded and repainted. <br /> 4. Drywall around Johnson control box to the left of Door 613B opening cut too large, needs to be patched and <br /> repaired. <br /> 5 . Drywall where it abuts the left jamb at Door 613B needs to be sanded and repainted. Irregular finish. <br /> 6. Drywall opening leading into Open Office Area 614 jambs need to be sanded and repainted where they are <br /> rough and irregular. Also, on the outside corners of this opening vinyl base needs to be <br /> re-secured. <br /> 7. Finish tape still installed on the vinyl base in this area. <br /> 8. Drywall to the bottom left above the vinyl base of Door 615 needs to be sanded and repainted very rough and <br /> irregular. <br /> 9 . Drywall where it abuts the left side of Door 615 needs to be sanded, caulked and repainted. <br /> 10. Drywall at the head of Door 615 needs to be sanded, caulked and repainted. <br /> 11 . Drywall to the top right of Door 615 needs to b sanded and repainted. <br /> 12. Right side of hollow metal door fame needs to be sanded and repainted. <br /> D O N A D I O <br /> & Associates, Architects, P.A . <br />