Laserfiche WebLink
L <br />9. Empty installed pipe shall be secured against flotation due to potential trench <br />flooding by timely placement of sufficient backfill or approved anchoring <br />devices sufficient to resist pipe buoyancy. <br />3.09 INSTALLATION OF FITTINGS <br />A. Fittings, plugs, and caps shall be set and jointed to pipe in the manner heretofore specified <br />for cleaning, laying and jointing pipe. <br />B. Installation of manholes shall conform to the details as shown on the Drawings and, <br />unless otherwise specified, shall conform with Section 425 of the 1986 Edition of the <br />Florida D.O.T. Standard Specifications for Road and Bridge Construction. Backfill shall <br />be placed in lifts not to exceed 12 inches loose depth and compacted to 95 percent of <br />maximum density per AASHTO T-180 in unpaved areas and to required subgrade <br />density in areas of paving or curbing. <br />C. Density tests shall be taken on the compacted backfill at all manholes. There shall be a <br />minimum of one test location for each manhole. The test location shall be taken at the <br />location designated by the Engineer's representative. The density tests shall be taken at <br />each location at one foot intervals beginning at the bottom of the excavation and ending at <br />the final grade. The costs of all testing shall be paid for by the Contractor. <br />3.10 INSTALLATION OF DETECTABLE BURIED WARNING TAPE <br />Tape shall be attached to the pipe for its entire length. Tape shall also be placed at a maximum <br />depth of 12 inches below finished grade directly above the pipe centerline. Following <br />placement of tape, the trench shall be backfilled with due caution to prevent displacement or <br />damage to the tape. <br />3.11 INSTALLATION OF DETECTABLE BURIED TRACE WIRE <br />Trace wire shall be installed on all pipe and fittings, with splices, branches, connections and <br />terminations as shown on the plans. <br />3.12 AS -BUILT DRAWINGS <br />During the installation of gravity sewer lines, the Contractor's Registered Florida Surveyor <br />and Mapper shall keep accurate records of the As -Built construction showing the <br />location of all changes in elevation, alignment, services, utility crossings, structures <br />and similar data. Items shall be located from permanent objects such as centerline of street, <br />manholes, valves, etc. Immediately upon completion of the sanitary sewer inverts and prior to <br />placement of roadway base, the Contractor shall deliver to the Engineer an As -Built Drawing, <br />signed and sealed by a Florida registered surveyor, showing the manhole separations, inverts and <br />rim elevations. <br />END OF SECTION <br />02530-9 <br />6 <br />02530 — Gravity Sanitary Sewer Piping <br />